PNS630 Handheld Analyzer User Manual
52
9.1 SMV detect
In SMV detect, all the control block information in the net will be displayed here.
Choose the control blocks required to phase check or analyzer the messages.
9.2 RMS
In SMV detect interface, choose the required SMV message and press Enter to enter
into the SMV interface. Here it shows all the SMV information such as amplitude, angle
and frequency. All the information will be refreshed per 1s.
SMV RMS interface
If there are more than two control blocks are chosen, press Control block to swtich
between different blocks.