Input Power Cable Length
1.4m / 4.7ft
Screen Cable Length
1.7m / 5.6ft
Sensor Length
2.0m / 6.4ft
Maximum Output - Resistive Load
(Such as ordinary fan, heating rod etc.)
1100W (110V)
Maximum Output - Inductive Load
(Such as compressor, heat pump etc.)
800W (110V)
Start-up amp MAX. 16A
Ambient Temperature
5 ~ 140 °F
Ambient Humidity
20~85% (No Condensate)
Note:
The maximum
continuous
current
of designed circuit is
12A
, however,
we still recommend using the thermostat under above listed output load for
durability and safe use.
Enter Setup Mode:
Press and hold “SET” key over 3 seconds to enter (or quit) parameters setup
mode, menu code will be displayed in flashing status. Short press “
▲
” or “
▼
”
the first time to show the default (last time) setting value. Press “SET” key to
cycle through all the setting menu.
Note:
1) Press and hold
“
▲
” or “
▼
”
can adjust the number more quickly.
2) If there is no further operation for
30 seconds
, system will quit setting mode
and return to normal temperature display mode,
all setting changes will be