 use or store the device in an environment of high temperature, 

humidity, explosive or inflammable field. 

6. 

NOTE:

 If the output relays are used over their life expectancy, contact 

fusing or burning may occasionally occur. Please always consider the 

application conditions and use the output relays within their rated load. 

 

 

Dual Relay Output (Heating and Cooling) 

 

*

 Separate Heating and Cooling Setpoint

 

* Pre-wired plug and play design 

* Large backlight LCD display 

* Waterproof NTC sensor 

* Temperature calibration function 

* Compressor delay protection time setting   

* High and low temperature alarm setting   

* Sensor fault alarm function 

 

 

1.

 

Functional Buttons:

 “

SET

”, “

” & “

” 

 

2.

 

Indicator Light Status:

 

 

ON: Refrigeration is in working state;   
FLASHING: Compressor delay state; OFF: Not working. 

 

 

Summary of Contents for PN160

Page 1: ...User Manual Model No PN160 Thank you for purchasing the Temperature Controller by Poniie Please read this manual carefully before using this product ...

Page 2: ...shock or personal injury read the Safety Information carefully before using the Thermostat 1 DO NOT use the device on anything that could possibly have a rating and start up amp greater than required see Technical Specifications part Note Induction motors such as air conditioners refrigerators space heater freezers and pumps may have a start up amp of 2 to 8 times the continuous rating 2 DO NOT di...

Page 3: ... use the output relays within their rated load Dual Relay Output Heating and Cooling Separate Heating and Cooling Setpoint Pre wired plug and play design Large backlight LCD display Waterproof NTC sensor Temperature calibration function Compressor delay protection time setting High and low temperature alarm setting Sensor fault alarm function 1 Functional Buttons SET 2 Indicator Light Status ON Re...

Page 4: ...1 Hd Heating Differential HD t52 Cooling Temperature Setpoint TS2 Cd Cooling Differential CD Pt Compressor Protection Time PT Hr High Ringing Alarm Hr Lr Low Ringing Alarm Lr CR Temperature Calibration CA Sensor fault alarm Temperature Control Range TS1 HD TS2 CD Setpoint TS1 Range 19 9 TS2 Setpoint TS2 Range TS1 199 9 High Alarm Hr Limit TS2 199 9 Low Alarm Lr Limit 19 9 TS1 Calibration CA Range ...

Page 5: ... we still recommend using the thermostat under above listed output load for durability and safe use Enter Setup Mode Press and hold SET key over 3 seconds to enter or quit parameters setup mode menu code will be displayed in flashing status Short press or the first time to show the default last time setting value Press SET key to cycle through all the setting menu Note 1 Press and hold or can adju...

Page 6: ...in most cases Cd Cooling Differential set upper range trigger how far from the TS2 setpoint temp can it drift before turning on cooling Pt Compressor Protection Time how long it will keep the refrigerating compressor off between cycles Hr High Ringing Alarm Limit set the temperature at which it will start beeping to notify you that the temperature has gone too high Lr Low Ringing Alarm Limit set t...

Page 7: ...S2 larger 1 1 TS 1 TS2 Limit Adjust Reminder Set TS1 smaller 1 1 Temperature Control Range Setting TS1 HD TS2 CD For example set TS1 77 F HD 2 F TS2 88 F and CD 3 F then when measured temperature is higher or equal to 91 F TS2 CD system enters refrigeration status when temperature decline to 88 F TS2 stop refrigeration when measured temperature is lower or equal to 75 F TS1 HD system enters heatin...

Page 8: ... refrigerating compressor off between cycles to protect your compressor That means compressor won t start refrigeration immediately but waiting for a delay time if it falls into the PT time frame Delay time will be calculated right after the refrigeration stops 1 3 Temperature Calibration CA When there is deviation between measured and actual temperature use calibration function to align the tempe...

Reviews: