3
blue for over 60 seconds.
Battery system failed in self-
inspection.
Reboot the battery system.
(10)
The Status Indicator on at least one battery module keeps blinking in
blue for over 30 seconds
Failure in CAN
communication.
Reconnect communication cable between
BCMS and battery module, then reboot the
system.
(11)
The Status Indicator on BCMS module/battery system/battery module
is solid yellow while SOC is 0%.
Low battery.
Charge the battery.
(12)
The Run Indicator on Universal PCS is solid red.
Inverter unit fault, including
overload, short circuit, grid
over voltage,
overfrequency, etc.
Check if the load is abnormal. Restart
Universal PCS. If it is not recovered, shut it
down and contact us.
Abnormal
connection/voltage of
batteries.
Check battery connection and battery
voltage. Restart Universal PCS. If it is not
recovered, shut it down and contact us.
(13)
The Run Indicator on Universal PCS is solid yellow.
PV charging unit fault, e.g.
PV input over-voltage.
Check PV input voltage. Restart Universal
PCS. If it is not recovered, shut it down and
contact us.
Abnormal
connection/voltage of
batteries.
Check battery connection and voltage.
Restart Universal PCS. If it is not recovered,
shut it down and contact us.
(14)
The Run Indicator on Universal PCS is blinking green, and the Status
Indicator on Universal PCS is blinking blue.
Inverter unit/PV charging
unit is upgrading.
Wait until upgrade is finished. If the blinking
blue keeps, restart Universal PCS. If it is not