2
(4)
The Network Indicator on Universal PCS is always solid white.
Something goes wrong with
the router or Internet.
Check your internet status. Reset the router
if necessary.
(5)
Failed to start the generator remotely.
The generator may not work
properly.
Check the generator.
The remote control cable is
disconnected.
Check and reconnect the cable.
(6)
The Status Indicator on BCMS module/battery system is solid red and
the Status Indicator on at least one battery module is solid red
The battery system is in the
most critical level protection
mode.
Charge the battery, or reboot the battery
system If it is not recovered, shut it down and
contact us.
(7)
The Status Indicator on BCMS module/battery system is solid red and
the Status Indicator on every battery module is solid green.
Battery system over-
current/ short circuit
protection.
Disconnect output switch of battery system,
check if there is an external short circuit, and
reboot the battery system. If it is not
recovered,, shut it down and contact us.
(8)
The Status Indicator on BCMS module/battery system is solid red and
the Status Indicator on at least one battery module is solid yellow or off.
The battery system is in the
low voltage protection
mode.
Charge the battery.
The battery system is in the
High voltage protection
mode.
Check if the communication cable for BCMS
and EMS is disconnected;
Leave it switched ON for 30 minutes;
If it is not recovered, shut it down and
contact us.
(9)
The Status Indicator on BCMS module/battery system keeps blinking in
Summary of Contents for iCAN NetZero Plus