![POMCube iCAN Mini 3500 User Manual Download Page 9](http://html.mh-extra.com/html/pomcube/ican-mini-3500/ican-mini-3500_user-manual_1578666009.webp)
8
2.2 Connecting wire specifications and circuit breaker model selection
Methods of connecting wire and installation must abide by national and local electrical specification
requirements.
Recommendation for PV array connecting wire specifications and circuit breaker model selection:
Because the output current of the PV array is influenced by the type, connection method and illumination
angle of the solar cell module, the minimum wire diameter of the PV array is calculated in accordance with
the short circuit current of the PV array. Please refer to the short circuit current value in the solar cell
module specifications (the short circuit current remains the same when the solar cell module is connected in
series; the short circuit current is the total of the short circuit currents of all parallel assemblies when
connected in parallel). The short circuit current of the array cannot exceed the PV maximum input current
Please refer to the following table for the PV input wire diameter and switch:
Model No.
Recommended wire
diameter of PV array
Recommended air switch or circuit
breaker model
iCAN Mini 3500
10mm
2
/8AWG
2P—63A
Note: The voltage connected in series must not exceed the maximum PV input open circuit voltage of 145V.
Please refer to the following table for the recommended AC input wire diameter and switch:
Model No.
Recommended wire
diameter of utility power
Recommended air switch or circuit
breaker model
iCAN Mini 3500
10 mm
2
/7AWG
2P—63A
Note: There is corresponding circuit breaker at the wire connection points of the utility power, so there is no
further circuit breaker needs to be added.
Recommended battery input wire diameter and switch model selection
Model No.
Recommended wire
diameter of battery
Recommended air switch or
circuit breaker model
iCAN Mini 3500
25mm
2
/4AWG
2P—100A
Recommended AC output connecting wire specifications and circuit breaker
model selection
Model No.
Recommended wire diameter
of load
Recommended air switch or circuit
breaker model
iCAN Mini 3500
10mm
2
/7AWG
2P—40A
Note: The wiring diameter is for reference only. If the distance between the PV array and iCAN Mini or
Summary of Contents for iCAN Mini 3500
Page 1: ...iCAN Mini User Manual Model iCAN Mini 3500 ...
Page 6: ...5 ...