18
4.3 Parameter setting
Operating instruction for keys: press ‘SET’ to enter or exit setup menu, then Parameter #00 will flash. Press
‘UP’, ‘DOWN’ and ‘ENT’ to edit the parameters when parameter is flashing, then press ‘ENT’ to confirm
changes, finally press ‘ENT’ to exit.
Parameter
No.
Parameter
name
Setting
option
Description
Detailed description
00
Exit setting
menu
[00] ESC
Exit setup menu
01
Output
source
priority
[01] SOL
Solar first
Solar first mode, when solar
power is not available or the
battery capacity is lower than the
settings of parameter [04] power
source is switched to utility
power.
[01] UTI
Utility first
Utility first, power source is
switched to inverter only when
utility power is not available.
[01] SBU
(default)
Inverter first, default
Inverter first, power source is
switched to utility power only
when battery is under-voltage or
the battery capacity is lower than
the settings of parameter [04].
02
Output
Frequency
[02] 50Hz
230V
Bypass automatically adapts.
When utility power is available,
bypass automatically adapts the
frequency of utility power. When
utility power is not available, the
output frequency can be set via
menu. Default frequency: 230V –
50.0Hz; 120V ~60.0Hz
[02] 60Hz
120V
03
AC Input
Voltage
Range
[03] APL
(default)
Applicable on 230V
device ONLY
AC Input Voltage Range.
Setting range (230V): 90V~280V
Setting range (120V): 90V~140V
[03] UPS
Applicable on 230V
device ONLY
AC Input Voltage Range.
Setting range (230V):
170V~280V
Setting range (120V): 90V~140V