Switch OFF the circuit breaker at the battery end, then the rocker switch ON the right side of iCAN Mini.
The "AC / INV" flashes to indicate that the inverter is working normally. Again, switch OFF the circuit
breaker of PV array and utility power. After the AC is outputted normally, turn on AC load one by one, to
avoid the protection action caused by a large momentary impact from the simultaneous startup of the load.
Therefore, iCAN Mini will perform normally according to the set mode.
Note: If power is supplied to different AC loads, it is recommended to first power a load with a large inrush
current. After the load is stable, turn on the load with a smaller inrush current.
Note: If iCAN Mini does not work properly or the display of LCD/indicator is abnormal, refer to Section 6
for troubleshooting.
3. Working mode
3.1 Charge mode
Solar energy first:
Solar power is primary source for charge of battery, and charge is supplied by
utility power only when solar power is not available. This mode is to fully utilize solar power in the
daytime and utility power in nighttime to maintain the battery capacity, and it is suitable for the place
in which power grid is relatively stable with expensive electricity price.
Utility first:
Utility power is primary source for charge of battery, and charge is supplied by solar
power only when utility power is not available.