5
5.. Re
Repe
pea
at
t st
step
eps
s 3
3
and
and 4
4
until all desired scan points are defined.
until all desired scan points are defined.
To delete defined scan points, select the GRID mode using the MODE key on
To delete defined scan points, select the GRID mode using the MODE key on
the hand set (L
the hand set (L
ED
ED
GRID is lit up). The TEACH key now functions as DEL key
GRID is lit up). The TEACH key now functions as DEL key
(for deleting).
(for deleting).
6.
6. Usin
Using the arro
g the arrow key
w keys, move t
s, move the lase
he laser beam for
r beam forward
wards or back
s or backwards t
wards to the
o the
scan point you want to delete.
scan point you want to delete.
7.
7. Pres
Press the D
s the DEL ke
EL key and th
y and the selec
e selected sc
ted scan poin
an point is dele
t is deleted.
ted.
8
8.. Re
Repe
pea
at
t st
step
eps
s 6
6
and
and 7
7
until all desired scan points are deleted.
until all desired scan points are deleted.
When the PSV is controlled via the software (L
When the PSV is controlled via the software (L
ED
ED
s REMOTE and LLO are lit
s REMOTE and LLO are lit
up), you can use
up), you can use the software to define and delete
the software to define and delete scan points, please refer to
scan points, please refer to
your software manual.
your software manual.
When the PSV is controlled via the software (L
When the PSV is controlled via the software (L
ED
ED
s REMOTE and LLO are lit
s REMOTE and LLO are lit
up), all settings are adjusted via
up), all settings are adjusted via the software, refer to your software manual.
the software, refer to your software manual.
In this case the
In this case the keys FUNCTION and SETTIN
keys FUNCTION and SETTING on the
G on the front of the controller
front of the controller
do not have a function.
do not have a function.
You will find information on setting the measurement range and the filters in
You will find information on setting the measurement range and the filters in
sec
sec
ti
ti
on
on
4.2
4.2
..
When the controller is operated without the
When the controller is operated without the software
software, you can
, you can set the
set the
measurement range and the filters via a menu on its display using the keys
measurement range and the filters via a menu on its display using the keys
FUNCTION and SETTING (refer to
FUNCTION and SETTING (refer to sec
sec
tio
tio
n
n
5.1
5.1
2
2
).
).
Overranging is indicated in the software. Please refer to your
Overranging is indicated in the software. Please refer to your software
software
manual.
manual.
If the L
If the L
ED
ED
OVER on the front of the controller is lit up continuously, it means
OVER on the front of the controller is lit up continuously, it means
that the measurement range set is
that the measurement range set is being exceeded. In this case the
being exceeded. In this case the next
next
highest measure
highest measurement range must be selected. Y
ment range must be selected. You will find further informa
ou will find further information
tion
on setting the measurement range in
on setting the measurement range in sec
sec
tio
tio
n
n
4.2
4.2
.1
.1
..
To get a 3D view style of the data, you have to define connections in the software. Please
To get a 3D view style of the data, you have to define connections in the software. Please
refer to your software manual.
refer to your software manual.
If you press the DEL key for more than approximately one second, the scan points will be
If you press the DEL key for more than approximately one second, the scan points will be
deleted one after the other!
deleted one after the other!
Summary of Contents for PSV 300
Page 48: ......
Page 64: ......
Page 73: ...Figure 7 2 Views of the scanning head OFV 056 Figure 7 2 Views of the scanning head OFV 056...
Page 76: ......
Page 92: ......
Page 93: ...Figure D 1 PSV 300 declaration of conformity Figure D 1 PSV 300 declaration of conformity...
Page 94: ......