FS3-3 Assembly July 2016
Page 8 of 16
from sink (fresh)
to pump
inlet
from waste
tank (recirc)
handle direction
arrow up = fresh
arrow down = recirc
Step 6: Hose Connections
Route the hose coming from the rear of the
waste tank through the 1-3/8” dia. hole in the
base,
(located closest to the right-hand side of
the base).
Place a PC-000352 hose clamp on
the end of the hose and push the end of this
hose onto the discharge side of the pump.
Tighten the clamp. Place a PC-000352 hose
clamp on the end of the hose coming from the
right-hand side of the slot in the fl oor. Push the
end of this hose on the fi tting at the bottom of
the waste tank, and tighten the clamp. Route
the remaining hose over the other hoses and
through the 1-3/8” hole in the base. Place
a PC-000352 hose clamp on the end of the
hose, push the hose onto the intake side of the
pump, and tighten the hose clamp.
Out To Waste Tank Bowl
In From 3-Way Valve
Step 7: Cabana to Base
(Continued)
Carefully stand the unit upright. Starting
with the left of the unit, drive a PC-000192
sems screw through the pre-drilled hole in
the front of the side panel.
BE SURE NOT
TO OVERTIGHTEN AND STRIP OUT THE
PLASTIC.
Continue around the left side of
the unit, until you reach the rear extrusion.
Repeat this process with the right side of the
unit, starting with the front.
9
1
3
4
2
8
7
6
13
12
11
5
10
14
PC-000192 Sems
(10) Used in this step