17
SANDOR WS SMA
POLITEC | INSTALLATION MANUAL - VER.3.1
N.B.:Optical synchronism requires greater attention
during the installation phases, in particular, that the
receiving column is not affected by other sources of
IR light.
To be absolutely certain that the alignment of the
optics is correct (and therefore no false alignments
due to the transmission of other infrared sources,
such as other barriers of the same system as well as
gate photocells) cover the TRANSMITTER optic with
your hand: if the RECEIVER continues to give a
continuous beep, it means that it sees another
infrared source that must be turned off and
eliminated.
At the end of the operation, remove the screen which acts as an attenuator, making sure to have
found the optimal value.
RX 1
TX 1
RX 2
TX 2
RX 3
TX 3
RX 4
TX 4
N.B.:During the alignment test phase, the
activation of a TX transmitter determines the
automatic shutdown of the other TX optics in
the column.
•
After aligning all the optics, set DIP 1 on the transmitter motherboard and DIP 10 on the receiver
motherboard to OFF, to automatically activate the
WALK TEST
phase for 60 seconds, the barrier
will emit a continuous acoustic signal, in case of interruption of a beam (two if configured in
AND) to indicate the correct operation of all the optics.At the end of the time the barrier is ready
for its normal operation.