25
SANDOR WS SMA
POLITEC | INSTALLATION MANUAL - VER.3.1
Repeated false alarms
If they are caused by the passage of animals, use the AND,
BEAM 1 functions or increase the intervention time.
Check the alignment accuracy of each individual optic and,
if necessary, carry out the procedure by performing a
complete scan, making sure that there are no light sources
that can influence the calibration.
To avoid radio disturbances, use a shielded cable with the
braid to the negative of the terminal board as the
connection between the wireless transmitter and the
barrier;
The
system
goes
into
disqualification even in the absence
of fog
Check the alignment accuracy of each individual optic and,
if necessary, carry out the procedure by performing a
complete scan, making sure that there are no light sources
that can influence the calibration;
For more precise alignment, position one side of the
column cover in front of the lenses in order to have two
surfaces interposed between TX and RX to double the
attenuation of the beam.