8.Barrier positioning
10
SANDOR WS SMA
POLITEC | INSTALLATION MANUAL - VER.3.1
8.1 Precautions before installation
Before placing the barriers outdoors, you must bear in mind that the infrared beam has a conical
shape: the greater the distance between the column, the greater the diameter of the cone when it
arrives.
In order to avoid false alarms, it is advisable to place the barriers away from reflecting surfaces, such
as walls or anything that can attenuate the signal.
DO NOT place the barriers if there are plants, bushes or fixed objects in the range that obstruct
the signal and create "grey areas".Leave a corridor of 50cm for distances between columns
greater than 50m
TX
RX
TX
RX
DO NOT place barriers close to roads: vehicle lights directed towards the RX could create
disturbances
DO NOT place barriers near automatic gates: photocell signals can create interference.
RX
DO NOT place the barriers close to walls, without spacing the columns with adequate
brackets, as the signal quality may decrease
RX
Summary of Contents for SANDOR WS SMA
Page 27: ......
Page 28: ...For technical support contact your security systems distributor...