I can't align
Check that there are no obstacles of any kind interposed
between RX and TX and that the conditions of the site do
not represent an impediment;
Make sure that the TX is in the test phase (orange LED of
the optic in question on and the others off);
Make sure that the connectors are well inserted and that
the DIP configuration is correct;
Make sure there are no external light sources that
interfere with the correct reading of the signal (gate
photocells, other barriers, infrared etc.);
After accurately aligning the sensor
(LED light on steady and continuous
BEEP) the system remains in alarm
Check which receiver optic does not pick up the
corresponding transmitter.To do this set the AND mode, if
the barrier is no longer in alarm, obscure each beam
individually finding the one that does not generate the
general alarm, this beam is not aligned;
Make sure that the connectors are well inserted and that
the DIP configuration is correct;
Make sure there are no external light sources that
interfere with the correct reading of the signal (gate
photocells, other barriers, infrared etc.);
The system goes into alarm with fog
and rain
Check the alignment accuracy of each individual optic and,
if necessary, carry out the procedure by performing a
complete scan, making sure that there are no light sources
that can influence the calibration;
Check that the fog disqualification function is active.
Make sure that the structure is well sealed and check that
there are not already elements inside which could create
disturbance (water, insects etc.);
For more precise alignment, position one side of the
column cover in front of the lenses in order to have two
surfaces interposed between TX and RX to double the
attenuation of the beam.