LIMITED WARRANTY 

Manufacturer warrants to the purchaser (the “Purchaser”) that the Product, including component 
parts, is free from material defects in material and workmanship, under normal use and service 
for a period of 1 (one)  year

 

(the “Warranty Period”) 

provided, however

, that the foregoing 

warranties are expressly contingent (and shall otherwise be void) upon use of the Products in 
accordance with specifications and without misuse, abuse, or abnormal use, accident, damage, 
alteration, or modification thereto or improper or unauthorized repairs or improper maintenance. 
Manufacturer shall not be responsible for any damage caused by an attempt of user to charge 
non-rechargeable batteries and any such actions shall void manufacturer’s warranty. Non-
substantial variations of performance from the documentation do not establish a warranty right. 

EXCEPT FOR THE FOREGOING EXPRESS WARRANTIES STATED HEREIN, AND FOR 
ANY WARRANTY, CONDITION, REPRESENTATION OR TERM TO THE EXTENT TO 
WHICH THE SAME CANNOT OR MAY NOT BE EXCLUDED OR LIMITED BY LAW 
APPLICABLE TO PURCHASER IN HIS/HER/ITS JURISDICTION, THE PRODUCTS AND 
SERVICES HEREUNDER ARE PROVIDED “AS IS AND WITH ALL FAULTS” AND, TO 
THE MAXIMUM EXTENT PERMITTED BY LAW, MANUFACTURER DISCLAIMS ALL 
OTHER WARRANTIES, OF ANY KIND, EITHER EXPRESS, OR IMPLIED, INCLUDING, 
WITHOUT LIMITATION, IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS 
FOR A PARTICULAR PURPOSE, INTEGRATION, SATISFACTORY QUALITY, 
NONINFRINGEMENT OR ANY WARRANTIES ARISING FROM COURSE OF DEALING 
OR COURSE OF PERFORMANCE. PURCHASER ASSUMES ALL RISKS AND 
RESPONSIBILITIES FOR SELECTION OF THE PRODUCT TO ACHIEVE HIS/HER/ITS 
INTENDED RESULTS, AND FOR THE INSTALLATION OF, USE OF, AND RESULTS 
OBTAINED FROM THE PRODUCT. MANUFACTURER DOES NOT WARRANT THAT 
THE PRODUCTS AND SERVICES HEREUNDER WILL MEET PURCHASER'S OR USERS' 
REQUIREMENTS OR WILL OPERATE IN THE COMBINATIONS WHICH MAY BE 
SELECTED BY PURCHASER OR  USER OR THAT THE SERVICES HEREUNDER OR 
THE OPERATION OF THE PRODUCTS WILL BE SECURE, ERROR-FREE, OR 
UNINTERRUPTED, AND MANUFACTURER HEREBY DISCLAIMS ANY AND ALL 
LIABILITY ON ACCOUNT THEREOF TO THE MAXIMUM EXTENT PERMISSIBLE 
UNDER APPLICABLE LAW. MANUFACTURER DISCLAIMS ANY AND ALL LIABILITY 
FOR THE LOSS OF DATA DURING ANY COMMUNICATIONS AND ANY LIABILITY 
ARISING FROM OR RELATED TO ANY FAILURE BY MANUFACTURER TO 
TRANSMIT ACCURATE OR COMPLETE INFORMATION TO PURCHASER. 

EXCLUSIVE REMEDY

 

Other than termination of your purchase agreement

 

due to Manufacturer 's breach, as Purchaser’s 

exclusive remedy for any defect or nonconformity in the Product, Purchaser shall obtain from 
Manufacturer repair or replacement of the Products containing such defect or nonconformity 
(“Affected Products”). In furtherance of such undertaking, if Purchaser reasonably believes that 
any Product contains a defect or nonconformity for which Manufacturer is responsible, 
Purchaser shall inform Manufacturer of the nature of such defect or nonconformity in reasonable 
detail and shall request authorization from Manufacturer to return the Affected Products to 
Manufacturer for repair or replacement. All Products so returned shall be shipped prepaid or 
otherwise delivered to Manufacturer 's facility or authorized service center. If Manufacturer fails 
to repair or replace the Affected Products within a reasonable time after Purchaser has so 
returned them to Manufacturer, Purchaser shall be entitled to repayment or credit of the original 
price of the defective or nonconforming Product as its exclusive further remedy. 

Summary of Contents for PM 2012M

Page 1: ...COMBINED CHEMICAL AGENT AND GAMMA RADIATION DETECTOR PM2012M Models PM 2012M PM 2012MA PM 2012M Operation Manual...

Page 2: ...ates endeavor to assure that their published engineering specifications and manuals are correct Despite these efforts errors can occur Polimaster Ltd and its affiliates reserve the right to correct an...

Page 3: ...ound the world that have recognized the capability and quality of Polimaster s instruments to assist them in their daily detection operations The PM2012M PM2012MA PM2012MB are ideally suited for a lar...

Page 4: ...INSTALLATION OF USE OF AND RESULTS OBTAINED FROM THE PRODUCT MANUFACTURER DOES NOT WARRANT THAT THE PRODUCTS AND SERVICES HEREUNDER WILL MEET PURCHASER S OR USERS REQUIREMENTS OR WILL OPERATE IN THE C...

Page 5: ...S HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES Limitation on Liability Notwithstanding any provision to the contrary herein and with the exception of the claims of intellectual property rights...

Page 6: ...Detector Module 19 3 4 2 Checking the CWA Module 19 Chapter 4 Operation Guidelines 22 4 1 Introduction 22 4 2 Dose rate measurements 23 4 3 Dose measurements 24 4 4 Detection of the chemical warfare...

Page 7: ...assembling of the chemical agent detection module and removal of the radioactive source will result in radiation exposure To avoid radiation exposure never disassemble the chemical agent detection mod...

Page 8: ...strictly observed Do not operate the unit if it is damaged or damage is suspected Pack the unit in its original packing case and return to the manufacturer or authorized service center for servicing...

Page 9: ...transfer via USB with PC and via Bluetooth channel with smartphones The unit also detects vapors emitted from chemical warfare agents CWA organophosphorus compounds sarin soman V gases and arsenic co...

Page 10: ...dose equivalent for the PM2012M model for the PM2012MA PM2012MB models from 1 Sv to 9 99 Sv from 1 Sv to 14 9 Sv Main relative dose measurement error 15 Dose accumulation time up to 99 999 h PM2012M P...

Page 11: ...discharge of 8 kV contact discharge of 6 kV test level 3 Thresholds of detection of organophosphorus compounds arsenic containing compound 5 1 5 10 5 mg l detection time is less than 10 s 3 0 9 10 4...

Page 12: ...nents The PM2012M PM2012MA PM2012MB GP Alkaline LR20 size D Battery CWA simulator Measuring cup Fabric filter elements 1 and 2 white Fabric filter element black Bottle with filter filler Cleaning rod...

Page 13: ...13 OPTIONAL ACCESSORIES 220V 12V AC adapter and 9 36 V DC power cable Rotameter Infrared adapter ACT IR220L or IR 210B USB cable for PM2012MB...

Page 14: ...WA Module The analyzed air enters the unit via the inlet 1 and exits it via the outlet 11 The display 6 together with two color LEDs bars 3 and 3 along with the audible alert device 4 provides all rel...

Page 15: ...ion The Radiation Detector module continuously measures the ambient dose equivalent rate 10 and the ambient dose equivalent 10 of gamma and X ray radiation and the dose accumulation time If the preset...

Page 16: ...onitors the battery voltage and displays the battery sign with the analogue scale in the upper right corner If the battery is fully charged all five marks are displayed In case of critical discharge t...

Page 17: ...nnector is blue connector is To avoid spontaneous switching the CWA operating modes do not expose the instrument to strong constant magnetic fields 3 3 Instrument Turning On Off The instrument turns o...

Page 18: ...ts measurements but the CWA module is still not working To operate with the CWA module three control marks on the rotating head 2 Figure 2 1 are used module is switched off calibration mode CWA detect...

Page 19: ...d dose rate value exceeds the preset threshold an audible alarm will sound Remove the source The audible alarm should terminate in 30 seconds Figure 3 5 The mark of the geometrical center of the gamma...

Page 20: ...his mode ensures the additional blowing of the ionization chamber The instrument automatically returns to the calibration mode when the blowing is successfully completed CAUTION If the instrument cont...

Page 21: ...t 1 Figure 2 3 of the instrument and open it Red or yellow LEDs will blink L bar or GV bar respectively depending on the simulator type marked on its ends and the audible alarm will sound refer to sec...

Page 22: ...DE button Figure 3 2 can switch the unit to the PC communication mode and see the current time hours minutes and seconds Dose equivalent rate screen Dose equivalent screen Time screen PC communication...

Page 23: ...e screen Dose equivalent rate threshold screen Figure 4 2 The dose equivalent rate DER and DER threshold screens The manufacturer presets the DER threshold value at 1 Sv h The DER threshold setting ra...

Page 24: ...igure 3 2 To return to the dose indication press the SET button again Dose equivalent screen Dose accumulation time screen Dose equivalent threshold screen Figure 4 3 The dose equivalent DE dose accum...

Page 25: ...procedure the unit displays CHEM SEARCH ON refer to section 3 4 2 1 and Figure 3 7 switch the unit to the CWA detection mode turn the rotating head in the direction shown by the arrow to math the mar...

Page 26: ...tected concentration is higher than about 125 of the preset threshold value Triple discontinuous audible signal with 1 s interval The manufacturer sets the CWA vapor detection thresholds as follow for...

Page 27: ...requirements IBM PC Pentium III or higher 1 G free HDD space operating systems Microsoft Windows 7 Windows 8 or Windows 10 To use the PC communication mode install PM2012M Data Processing Software ref...

Page 28: ...ment non volatile memory instrument operation history DER values in set time intervals time and date when the instrument was switched on off time date and current DER value when the preset DER thresho...

Page 29: ...tion push the Home button iPhone and Android and switch off the Bluetooth channel as in par 2 4 The following operations can be conducted when the instrument is connected to smarthone in particluar to...

Page 30: ...e maintenance procedures Protect the instrument from shocks and mechanical impacts corrosive environments organic solvents and open fire 5 1 Maintenance schedule Task Frequency Refer To Cleaning of th...

Page 31: ...the rotating head 2 Figure 5 1 and the mark on the unit case align the unit vertically so that the inlet 1 Figure 3 2 is facing upward take the cleaning rod and a strip of cotton cloth 8 10 mm wide an...

Page 32: ...3 2 is facing upward take a medicine or measuring pipette with 10 15 drops 0 5 ml of rectified ethanol insert pipette into the inlet not deeper than 1 2 cm and put in ethanol drop by drop into the io...

Page 33: ...st of the micropump capacity Connect the lower silicone tube of the rotameter available as an option with the outlet 11 Figure 3 2 check that a seal is made tight Switch the instrument into the CWA mo...

Page 34: ...ded in the Accessories kit 10 fabric filter element 2 white included in the Accessories kit Figure 5 1 Filter construction The replacement procedure consists of the following steps turn the instrument...

Page 35: ...rough remove the fabric filter elements 9 and 10 install the new fabric filter elements 9 and 10 from the Accessories kit and the cleaned gauze 8 fill in the unit case with a fresh coal Figure 5 2 usi...

Page 36: ...d be fulfilled by the specially trained personnel at the manufacturer facility or authorized service center 5 6 Instrument decontamination The protective treatment includes external examination of the...

Page 37: ...isplays error messages Test failure Send the instruments to the manufacturer or authorized service center Instrument produces neither audible nor visual alarms in the CWA detection mode if the simulat...