Repair Manual
Macro 5 SLR Camera
51
Trigger PC Boards
Note:
Use a dump stick to fully discharge the strobe capacitors before
attempting to remove or replace the trigger PC board.
1. Removal (Figure 5-7)
a. Remove the left/right cover assembly as explained on page 39.
b. Remove the front cover assembly as explained on page 43.
c. Disconnect electrical cable J32 from the applicable trigger PC board.
d. Using a soldering iron and a solder sucker, unsolder the white trigger wire
from the trigger coil.
Note:
Be careful not to damage the trigger coil.
e. Using a torx driver, remove the two (2) screws securing the trigger PC
board to the front cover support mounts.
f.
Lift out the trigger PC board.
Caution: Shock Hazard - High Voltage
Summary of Contents for Macro 5 SLR
Page 33: ...Repair Manual Macro 5 SLR Camera 33 Section 4 Troubleshooting Diagnostics Module 34...
Page 76: ...Repair Manual Macro 5 SLR Camera 76 Figure 6 1 S1 S2 PC Board...
Page 77: ...Repair Manual Macro 5 SLR Camera 77 Figure 6 2 Encoder PC Board...
Page 78: ...Repair Manual Macro 5 SLR Camera 78 Figure 6 3 Trigger PC Board...
Page 79: ...Repair Manual Macro 5 SLR Camera 79 Figure 6 4 Strobe PC Board 1 of 1...
Page 80: ...Repair Manual Macro 5 SLR Camera 80 Figure 6 5 Strobe PC Board 2 of 2...
Page 81: ...Repair Manual Macro 5 SLR Camera 81 Figure 6 6 Logic PC Board 1 of 1...
Page 82: ...Repair Manual Macro 5 SLR Camera 82 Figure 6 7 Logic PC Board 2 of 2...
Page 83: ...Repair Manual Macro 5 SLR Camera 83 Figure 6 8 Communication PC Board...