Ranging (Aim) Lights Adjustment
1. Place the camera onto the test fixture as shown in Figure 3-1.
Figure 3-1 Camera Test Fixture
2. Set the magnification selector knob to its 1X position.
3. Turn on the camera.
4. Press the red shutter button lightly to turn on the range lights. The range
lights should be merged together and centered in the test target (Figure 3-2).
Note:
If the range lights are merged together and centered in the test
target, no adjustment is necessary.
If the range lights are not merged together or centered in the test
target, proceed to step 5 and adjust as needed.
Test Target
area
Camera
Test Fixture