10.28
ELECTRICAL
Charging Procedure
If battery voltage is 12.6 Vdc or less, the battery may need
recharging. When using an automatic charger, refer to the
charger manufacturer’s instructions for recharging.
Do not exceed 9 amps when charging the battery.
NOTE: Charge the battery using an automatic
charger that will not exceed 14.6 Vdc. An automatic
charger will signal when charging is complete.
NOTE: Allow the battery to stand disconnected for
at least 1-2 hours after being properly charged. If the
voltage drops below 12.6 volts, charging was
ineffective or the battery needs to be replaced.
NOTE: Follow the charger instructions supplied by
the manufacture regarding the order or connections,
switch positions and when to connect the charger to
an outlet.
STARTING SYSTEM
Troubleshooting
Starter Motor Does Not Run
• Battery discharged
• Loose or faulty battery cables or corroded connections
(see Voltage Drop Tests)
• Related wiring loose, disconnected, or corroded
• Poor ground connections at battery cable, starter motor
or starter solenoid (see Voltage Drop Tests)
• Faulty key switch
• Faulty starter solenoid or starter motor
• Engine problem - seized or binding (can engine be
rotated easily)
Starter Motor Turns Over Slowly
• Battery discharged
• Excessive circuit resistance - poor connections (see
Voltage Drop Test)
• Engine problem - seized or binding (can engine be
rotated easily)
• Faulty or worn brushes in starter motor
Starter Motor Turns - Engine Does Not Rotate
• Faulty starter drive
• Faulty starter drive gears or starter motor gear
• Faulty flywheel gear or loose flywheel
WARNING
An overheated battery could explode, causing severe
injury or death. Always watch charging times carefully.
Stop charging if the battery becomes very warm to the
touch. Allow it to cool before resuming charging.
State of
Charge
Voltage (DC)
Action
Charge
Time
100%
12.8 - 13.0
None, check
again in 3
months
None
Required
75% - 100%
12.5 - 12.8
May need
slight charge
3 - 6 hrs
50% - 75%
12.0 - 12.5
Needs Charge
5 - 11 hrs
25% - 50%
11.5 - 12.0
Needs Charge
At least
13 hrs
0% - 25%
11.5 or less
Needs Charge
At least
20 hrs
Summary of Contents for Ranger RZR SW
Page 4: ......
Page 12: ...1 8 GENERAL INFORMATION SAE Tap Drill Sizes Metric Tap Drill Sizes Decimal Equivalents ...
Page 14: ...NOTES GENERAL INFORMATION 1 10 ...
Page 48: ...NOTES MAINTENANCE 2 34 ...
Page 50: ...3 2 ENGINE ENGINE SPECIFICATIONS Crankcase Exploded Views ...
Page 51: ...3 3 ENGINE 3 Oil Pump Water Pump Engine Cover Exploded View ...
Page 52: ...3 4 ENGINE Stator Cover Starter Water Pump Oil Filter Pressure Relief Exploded View ...
Page 53: ...3 5 ENGINE 3 Cylinder Cylinder Head Piston Exploded View ...
Page 112: ...NOTES ENGINE 3 64 ...
Page 154: ...4 42 ELECTRONIC FUEL INJECTION Digital Wrench Feature Map ...
Page 192: ...NOTES BODY STEERING SUSPENSION 5 34 ...
Page 264: ...NOTES FINAL DRIVE 7 48 ...
Page 284: ...NOTES TRANSMISSION 8 20 ...
Page 324: ...10 18 ELECTRICAL COOLING SYSTEM SCHEMATIC Cooling System Break Out Diagram ...
Page 345: ......
Page 346: ......