10.31
ELECTRICAL
10
Battery Installation
1.
Clean battery cables and terminals with a stiff wire brush.
Corrosion can be removed using a solution of one cup
water and one tablespoon baking soda. Rinse well with
clean water and dry thoroughly.
2.
Route the cables correctly.
3.
Reinstall battery, attaching positive (+) (red) cable first and
then the negative (-) (black) cable. Coat terminals and bolt
threads with Nyogel™ Grease (PN 2871329).
4.
Reinstall the holder strap.
Battery Testing
Whenever a service complaint is related to either the starting or
charging systems, the battery should be checked first.
Following are two tests which can easily be made on a Sealed
Low Maintenance battery to determine its condition: OCV Test
and a Load Test.
OCV - Open Circuit Voltage Test
Battery voltage should be checked with a digital multitester.
Readings of 12.8 volts or less require further battery testing and
charging. See charts and Load Test.
NOTE: Lead-acid batteries should be kept at or near
a full charge as possible. If the battery is stored or
used in a partially charged condition, or with low
electrolyte levels, hard crystal sulfation will form on
the plates, reducing the efficiency and service life of
the battery.
NOTE: Use a voltmeter or multimeter to test batter
voltage.
Load Test
NOTE: This test can only be performed on machines
with electric starters. This test cannot be performed
with an engine or starting system that is not working
properly.
A battery may indicate a full charge condition in the OCV test
and the specific gravity test, but still may not have the storage
capacity necessary to properly function in the electrical system.
For this reason, a battery capacity or load test should be
conducted whenever poor battery performance is encountered.
To perform this test, hook a multitester to the battery in the same
manner as was done in the OCV test. The reading should be 12.6
volts or greater. Engage the starter and observe the battery
voltage while cranking the engine. Continue the test for 15
seconds. During cranking the observed voltage should not drop
below 9.5 volts. If the beginning voltage is 12.6 volts or higher
and the cranking voltage drops below 9.5 volts during the test,
replace the battery.
OPEN CIRCUIT VOLTAGE
State of Charge
Maintenance
Free
YuMicron
™
Type
100%
13.0 V
12.70 V
75% Charged
12.80 V
12.50 V
50% Charged
12.50 V
12.20 V
25% Charged
12.20 V
12.0 V
0% Charged
less than 12.0 V
less than 11.9 V
* At 80° F
NOTE: Subtract .01 from the specific gravity reading at 40° F.
CAUTION
To prevent shock or component damage,
remove spark plug high tension leads and
connect securely to engine ground
before proceeding.
Summary of Contents for 2008 ranger 700 xp
Page 1: ...POLARIS RANGER XP 700 4X4 RANGER 6X6 SERVICE MANUAL ...
Page 3: ...POLARIS RANGER XP 700 4X4 RANGER 6X6 SERVICE MANUAL ...
Page 15: ...1 12 GENERAL INFORMATION SAE Tap Drill Sizes Metric Tap Drill Sizes Decimal Equivalents ...
Page 118: ...4 8 FUEL INJECTION FUEL TANK Exploded View Fuel Flow ...
Page 136: ...5 4 BODY STEERING SUSPENSION Lower Body Components ...
Page 302: ...10 19 ELECTRICAL 10 COOLING SYSTEM Cooling System Break Out Diagram EY N 6OLT 0OWER ...
Page 327: ...11 1 WIRE DIAGRAM RANGER 700 EFI 4X4 6X6 CHASSIS PAGE 1 OF 2 ...
Page 328: ...11 2 WIRE DIAGRAM RANGER 700 EFI 4X4 6X6 CHASSIS PAGE 2 OF 2 ...
Page 329: ...11 3 WIRE DIAGRAM RANGER 700 EFI 4X4 6X6 DASH ...
Page 330: ...11 4 WIRE DIAGRAM RANGER 700 EFI 4X4 6X6 BREAKOUTS ...