User Configuration Parameter Commands
The following commands allow you to set and query the values of the TCM2.5/2.6’s user configuration
parameters. These parameters specify how the TCM2.5/2.6 will operate, such as damping, baud rate,
and so on. The TCM2.5/2.6 stores all parameter values in EEPROM when specified, so that after a
reboot or power cycling, it will return to the last configuration set. Note that any parameter that specifies a
numeric value must be specified with the appropriate units of the current setting.
b=
(Set Baud Rate)
Description
Sets the baud rate for the RS232 interface.
Note: This is now an immediate command
and a reset is no longer required.
Syntax
b=n<cr>
Output
:<cr><lf>
Valid Values
Input
Baud Rate
1
300
2
1200
3
2400
4
4800
5
9600 (default setting)
6
19200
7
38400
8
115200
Table 9: Valid
b=
Values
Example
b=5<cr>
!set baud rate to 9600 baud
:<cr><lf>
Query Response
b?
:b=