factory
(Factory Settings)
Description
Resets the TCM2.5/2.6 to the factory settings. The internal modes are set to the following
factory defaults
b=5
er=e
mpcal=d
ut=c
cc
et=d
sdo=t
damping=d
timeconst=8
sn=m
ec=e
halt=d
sp=8
em=e
ma=u
uc=d
ep=e
mag_dec=0.0
ui=d
Syntax
factory<cr>
Output
H0V0m0.00<cr><lf>
Example
factory<cr>
go
(Enter Continuous Sampling Mode)
Description
Enters the Continuous Sampling Mode (
go
). The TCM2.5/2.6 immediately begins
outputting sensors data at rate specified by the SP parameter, default is 8 Hz. Data is
automatically transmitted according to the Output Word Format (
sdo=
) currently specified.
To exit the TCM2.5/2.6 and return to Standby mode, issue the Halt Continuous Sampling
(
h
) command.
Syntax
go<cr>
Output
Selected data output word.
Example
go<cr>
Related Commands
s? (Single Update of Output Word)
h (Halt Continuous Sampling)