background image

000115682/151018/0 WallPro 

EN - 8

Fig. 4.3

•  Determine on which side

14

 you want to install the extraction 

arm (left or right). 

•  Install the reinforcement plate on that side of the filter unit 

with the 7 flange bolts M6x16. 

Fig. 4.3  Mounting of the reinforcement plate

4.3.2  Inlet non-return valve (assembly)

Applies to all types of units

You must install the assembly, that consists of an inlet flange 

with non-return valve, on the side panel of the filter unit. In 

case of a WallPro Double, you must install an assembly on 

both side panels. 

The side panels are universal, so you can install 

them either left or right. 

To install the assembly, do the following. 

Fig. 4.4

•  Depending on the mounting position

15

, determine the 

inside of the side panel. 

•  Put sealing material (E) around the inlet opening on the 

inside of the side panel. 

•  Insert the assembly from the inside of the panel through 

the opening. Make sure that the axis of the non-return 

valve is in vertical position (B). 

•  Attach the assembly (A) to the side panel with the 6 bolts 

M6, washers and nuts. 

•  Secure the non-return valve to the inlet flange with 2 

self-tapping screws (F+G). Two small holes in the inlet 

flange indicate the correct position. Make sure that you 

install one screw on top and the other one at the bottom of 

the assembly. 

•  Make sure that the non-return valve can fully open.  

In case of a LL-5.5/24 | Manual on/off switch on the 

hood, incl. LED working light (option)

•  Install the cable gland M16 + nut M16 (C). 

If not: 

•  Install the screw plug M16 + nut M16 (D). 

14.  In case of a WallPro Double you must install a reinforcement plate on both 

sides

15.  On the left or right side of the filter unit

A

B

E

F

G

C

D

A

B

E

F

G

C

D

Fig. 4.4  Inlet  non-return valve (assembly)

4.3.3  Side panel

In case of:

DM

Make sure that you have the 4 bolts M12 at hand 

that you need to install the arm bracket.
For the correct use of SealApplicator, refer to the 

instruction sheet that is supplied with the spray 

bottle. 
Refer to Fig. V on page 23 for the exact mounting 

position of the side panel with respect to the cover 

plates (top + bottom) . 

Fig. 4.5

•  (1) Remove the backing material of the seals.

•  (2) Spray SealApplicator lubricant on the seals

16

.

•  (3) Put the side panel 

within 60 seconds

17

 on the filter 

unit. 

•  (4) Align the side panel with the 4 bolts M12x30 into the 

cage nuts and partly tighten them

18

•  (5) Install the side panel with the 24 bolts M6x16 + sealing 

washers M6. 

•  (6) Disassemble the 4 bolts M12x30. 

16.  By the use of SealApplicator you can slightly shift the side panel to get the 

right position. After approx. 60 seconds the lubricant is dry so you cannot shift 

anymore.

17.  After approx. 60 seconds SealApplicator lubricant loses its functions and you 

cannot shift anymore. 

18.  You must remove them later on to install the arm bracket. 

Summary of Contents for WALLPRO

Page 1: ...www plymovent com EN Stationary filter unit EN Installation and user manual WALLPRO...

Page 2: ...of this document This publication is to be used for the standard model of the product of the type given on the cover page Thus the manufacturer cannot be held responsible for any damage resulting fro...

Page 3: ...e 3 1 Introduction 3 2 Product description 4 3 Safety instructions 5 4 Installation 6 5 Use 14 6 Maintenance 15 7 Troubleshooting 17 8 Spare parts 18 9 Electrical diagram 18 10 Disposal 18 CE declarat...

Page 4: ...product name serial number You can find these data on the identification plate 1 INTRODUCTION 1 1 Identification of the product The identification plate contains among other things the following data...

Page 5: ...A 160 2x KUA 200 n a n a 2 x 1000 m h 2 x 1450 m h WallPro Basic 1 inlet left or right 2 inlets left and right 1250 m h n a 2100 m h 2 x 1550 m h 1 For fan type FUA 3000 2 For fan type FUA 4700 Silenc...

Page 6: ...ations User manual Everyone working on or with the product must be familiar with the contents of this manual and must strictly observe the instructions therein The management should instruct the perso...

Page 7: ...icient approved fire extinguishers suitable for fire classes ABC Do not leave any tools or other objects in or on the unit The welding current return circuit between the workpiece and the welding mach...

Page 8: ...m s 160 Arm diameter 160 mm 200 Arm diameter 200 mm 3 Arm length 3 m 4 Arm length 4 m DM Direct mount EM External mount 11 The UL certification applies to the control box 12 For connection with the co...

Page 9: ...embly Make sure that the non return valve can fully open In case of a LL 5 5 24 Manual on off switch on the hood incl LED working light option Install the cable gland M16 nut M16 C If not Install the...

Page 10: ...3 3 Fig 4 6 Mounting of the arm bracket In case of WallPro Double DM If applicable Do the same procedure for the other arm bracket In case of EM Recommended installation height of the arm bracket at...

Page 11: ...s coupling Connect the air hoses22 in the connectors and B C 21 You do not need these four bolts anymore The other two bolts remain unused but must stay in the inlet flange 22 The different colours si...

Page 12: ...emove the blind plug C from the nearest left or right 24 cable gland B just below the indicator panel Feed the cable through the cable gland B inside the unit Tighten the cable gland 24 In case of a W...

Page 13: ...gurations with an imperial duct size 6 in or 8 in 28 160 mm 6 in or 200 mm 8 in depending on the inlet diameter 4 8 1 Dustbin extension set option For easy maintenance you can install the dustbin on t...

Page 14: ...e Power Thermal relay Range Setting Single FUA 3000 230 V 2 HP 4 0 6 3 A 5 2 A 460 V 2 HP 2 2 3 2 A 2 4 A 575 V 2 HP 1 7 2 4 A 2 1 A PowerPlus FUA 4700 230 V 3 HP 7 5 10 5 A 8 8 A Double 460 V 3 HP 4...

Page 15: ...paragraph 1 3 Fig 4 23 A B Fan outlet transition 4 11 Commissioning checklist Check Ref par OK 1 Are all cables correctly installed 4 9 1 2 Are the air hoses and correctly installed 4 9 1 3 Is the dir...

Page 16: ...filter cartridge refer to paragraph 6 2 To prevent unnecessary filter replacement make sure that compressed air is available and connected the pressure setting is correct refer to paragraph 4 9 2 5 3...

Page 17: ...replace the filter cartridge Personal protective equipment PPE Wear respiratory protection and protective gloves when you replace the filter cartridge WARNING Do not replace the filter cartridge whil...

Page 18: ...The washer is supplied with the new filter cartridge 34 The star knob is attached to a rope to prevent loss Turn the rotary knob A in vertical position to open the shut off valve If applicable energi...

Page 19: ...ue button Dust leakage from the hopper Sealing is insufficient The adhesive rubber strip is damaged or worn Replace the adhesive rubber strip The star knobs of the hopper are not fully tightended Full...

Page 20: ...ibility that the product WallPro which this declaration refers to is in accordance with the conditions of the following Directives Machine Directive 2006 42 EC EMC 2014 30 EU LVD 2014 35 EU ErP Direct...

Page 21: ...Dimens es FR Dimensions PL Wymiary A B C E D F G H WallPro mm inch A 700 27 6 B Single 1991 78 4 Basic Single PowerPlus 2059 81 1 Basic PowerPlus Double C 1236 48 7 D 975 38 4 E 764 30 1 F 123 4 8 G K...

Page 22: ...orking range Max distance Max angle Mounting position E Wall mounting F On a stanchion or similar NL Werkbereik Max afstand Max hoek E Wandmontage F DE Bereich E F FR Port e E F ES Alcance de trabajo...

Page 23: ...SET 5 SET 5 SET 5 SET 5 SET 1 Wall bracket 2x Bolt M10x30 2x Locknut M10 4x Washer M10 SET 2 Side panel 1x Screw plug M16 1x Nut M16 1x Cable gland M16 24x Bolt M6x16 24x Sealing washer M6 SET 3 Reinf...

Page 24: ...d e d installation E configuration des trous ES Altura de instalaci n recomendada E dise o de agujeros IT Altezza di installazione raccommandata E disposizione dei fori PT PL Zalecana wysoko monta u E...

Page 25: ...83 0040900010 0000117119 0000118185 0000117120 0000117546 0000117872 0000117875 0000117871 0000117900 0000118194 EN Exploded view filter unit WallPro NL Exploded view filterunit WallPro DE Explosionsz...

Page 26: ...alve 160 mm NRV 160 Terugslagklep 160 mm NRV 160 R ckschlagklappe 160 mm WallPro FR Pi ces d tach es ES Piezas de recambio IT Pezzi di ricambio 0000100306 FUA 3000 IEC 400V 3ph 50Hz FUA 3000 IEC 400V...

Page 27: ...Exploded view control box 0000102289 0000117869 0000117868 CE 0000118192 UL 0000101413 CE UL 0000102287 0000102288 0000117133 0000117134 0040900200 0000117870 0000117120 0000117873 0000117874 00001179...

Page 28: ...mbar sticker schaal 60Hz Differenzdruckschalter 6 50 mbar Aufkleber Skala 60Hz 0040900200 Thermal relay NTR 4 0 6 3 A Thermisch relais NTR 4 0 6 3 A Thermisches Relai NTR 4 0 6 3 A Control box FR Pi c...

Page 29: ...www plymovent com 000115682 151018 0 WallPro...

Reviews: