000115682/151018/0 WallPro
EN - 5
D Arm bracket
E Fan outlet transition
F Service panel
G RamAir™ pulse amplifier (filter cleaning system)
H Indicator panel
I Dustbin
J Control box
Fig. 2.1
A
B
C
H
F
E
G
I
J
D
Main components and elements
2.2
Operation
The WallPro works in accordance with the recirculation
principle. Welding fume is extracted through the hood of the
connected extraction arm(s) by the fan. The polluted air
passes the deflector plate(s)
5
behind the inlet opening(s) and
is cleaned by the filter cartridge. The welding fume particles
are collected at the outside of the filter cartridge. The cleaned
air is returned in the workshop through the outlet of the fan or
exhausted to the atmosphere via an outlet duct.
2.2.1 Filter cleaning system
The WallPro is provided with the RamAir™ pulse amplifier,
which thoroughly cleans the filter cartridge by compressed air
pulses from the inside out. Filter cleaning mainly takes place
offline (=while the fan is off)
6
. If the pressure drop over the
filter cartridge reaches the pre-set threshold value during use,
an online cleaning cycle takes place. You can activate the filter
cleaning system manually as well (both offline and online).
The dust and dirt particles fall into the dustbin.
Refer to paragraph 5.3 for more details about the
activation of the cleaning system.
5. To protect the filter cartridge and to distribute the air equally inside the unit
6. Offline filter cleaning is the most effective way of cleaning. The combination of
offline and online cleaning guarantee the optimum performance of the unit.
3
SAFETY INSTRUCTIONS
General
The manufacturer does not accept any liability for damage to
the product or personal injury caused by ignoring of the safety
instructions in this manual, or by negligence during
installation, use, maintenance, and repair of the product
mentioned on the cover of this document and any
corresponding accessories.
Specific working conditions or used accessories may require
additional safety instructions. Immediately contact your
supplier if you detect a potential danger when using the
product.
The user of the product is always fully responsible for
observing the local safety instructions and regulations.
Observe all applicable safety instructions and
regulations.
User manual
- Everyone working on or with the product, must be familiar
with the contents of this manual and must strictly observe
the instructions therein. The management should instruct the
personnel in accordance with the manual and observe all
instructions and directions given.
- Do not change the order of the steps to perform.
- Keep the manual with the product.
Users
- The use of this product is exclusively reserved to authorised,
trained and qualified users. Temporary personnel and
personnel in training can only use the product under
supervision and responsibility of skilled engineers.
- Stay alert and keep your attention to your work. Do not use
the product when you are under the influence of drugs,
alcohol or medicine.
- The product is not to be used by children or persons with
reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given
supervision or instruction.
- Children must be supervised not to play with the product.
Intended use
7
The product has been designed exclusively for extracting and
filtering gases and particles which are released during the
most common welding processes. Using the product for other
purposes is considered contrary to its intended use. The
manufacturer accepts no liability for any damage or injury
resulting from such use. The product has been built in
accordance with state-of-the-art standards and recognised
safety regulations. Only use this product when in technically
perfect condition in accordance with its intended use and the
instructions explained in the user manual.
Technical specifications
Do not change the specifications given in this manual.
Modifications
Modification of (parts of) the product is not allowed.
Installation
- The installation of this product is exclusively reserved to
authorised, trained and qualified engineers.
- The electric connection must be executed in accordance with
the local codes and requirements. Ensure compliance with
the EMC regulatory arrangements.
7. “Intended use” as explained in EN-ISO 12100-1 is the use for which the
technical product is suited as specified by the manufacturer, inclusive of his
directions in the sales brochure. In case of doubt it is the use which can be
deduced from the construction, the model and the function of the technical
product which is considered normal use. Operating the machine within the
limits of its intended use also involves observing the instructions in the user
manual.