background image

USER MANUAL

CO2 SCRUBBER

VERSION DS-2019-09

IHC Hytech B.V.

Ramgatseweg 27

The Netherlands

T +31 88 015 36 00

[email protected]

www.royalihc.com

4941 VN Raamsdonksveer

 

www.ihchytech.com

ROYAL

IHC

.COM

Summary of Contents for CO2

Page 1: ...USER MANUAL CO2 SCRUBBER VERSION DS 2019 09 IHC Hytech B V Ramgatseweg 27 The Netherlands T 31 88 015 36 00 hytech royalihc com www royalihc com 4941 VN Raamsdonksveer www ihchytech com ROYALIHC COM ...

Page 2: ...ctronic mechanical photocopying recording or otherwise without the prior written permission of IHC Hytech B V This publication remains the property of IHC Hytech B V and may not be passed loaned or given to any third party IHC Hytech B V reserves the right to make changes in design and specifications without notice 24 7 EMERGENCY LINE OPERATIONAL AND TECHNICAL ASSISTANCE 31 88 015 36 00 ...

Page 3: ...h diver decompression chambers and hyperbaric treatment chambers CORRECTIONS AND OR CLARIFICATIONS During the composition of this manual much attention has been given to avoid errors and mis takes If during the use of this manual errors or incomplete descriptions are found or if the reader considers that improvements are necessary to overcome any inaccuracies please inform us We appreciate any com...

Page 4: ...4 IHCHYTECH COM ...

Page 5: ...CANISTER 9 2 SAFETY PRECAUTIONS 11 2 1 GENERAL 11 2 2 WARNING SIGNS 11 2 3 GENERAL SAFETY MEASURES 11 2 3 1 MAINTENANCE AND REPAIR 11 3 INSTALLATION 13 3 1 MECHANICAL 13 3 2 ELECTRICAL 13 4 OPERATION 15 4 1 GENERAL 15 4 2 PERFORMANCE 15 4 2 1 PERFORMANCE DIAGRAMS 16 4 3 REPLACING OR REFILLING THE CANISTER 17 5 MAINTENANCE 19 5 1 GENERAL 19 5 2 SPARE PARTS AND ACCESSORIES 19 INDEX 21 ...

Page 6: ...6 IHCHYTECH COM ...

Page 7: ...otects the motor from environmental impacts such as raised oxygen levels humidity and pressure The canister can hold approx 7 5 kg 16 5 lbs of CO2 adsorbent and is connected to the motor by a bayonet locking mechanism for easy replacement The canister is provided with internal mesh of 0 3 mm to keep in the smallest grains One scrubber is capable of serving eight persons for more than 6 hours in a ...

Page 8: ... allows increase of the maximum operating pressure according to the graph below Specifications Dimensions L 422 mm 16 6 inch x W 226 mm 8 9 inch x H 245 mm 9 7 inch Weight complete unit empty 8 3 kg 18 3 lbs Weight complete unit full 16 kg 35 3 lbs Weight canister empty 2 3 kg 5 1 lbs Weight canister full 10 kg 22 Power supply 24 28VDC 2A Rotating speed 1400 3300 rpm Operating pressure Max 42 bar ...

Page 9: ...de HCL from vomit Hydrogen sulphite H2S from feces intestinal gas Carbonyl sulphite OCS from intestinal gas Hydrogen H from intestinal gas Methane CH4 from intestinal gas Carbondisulphite CS2 from intestinal gas Butyric acid C3H1COOH from intestinal gas The contamination scrubber canister contains a special blend of carbon molecular sieves and a catalyst and is stored in an air tight container Onc...

Page 10: ...10 Chapter 1 IHCHYTECH COM ...

Page 11: ...he warning signs are NOTE This indicates a situation that requires extra attention CAUTION This indicates a situation that can cause severe damage to the installation and or can result in injuries WARNING This indicates a situation that can cause severe injuries or death 2 3 GENERAL SAFETY MEASURES 2 3 1 MAINTENANCE AND REPAIR Maintenance and repair jobs must only be performed by qualified personn...

Page 12: ...USER MANUAL CO2 SCRUBBER VERSION CS 2019 09 Chapter 2 12 ...

Page 13: ...e of at least 75 mm 3 must be provided on each side of the unit to ensure proper gas flow Also keep free space on the side of the canister for removal of the canister 3 2 ELECTRICAL The scrubber can be used with a pre set speed or external speed control function Use the specified pins on the connector and place the jumper inside the scrubber to configure the desired function See table and pictures...

Page 14: ... 1 Black wire 24 VDC 5 Jumper 2 White wire 0 VDC 6 Jumper in position for external speed control 3 Red wire 0 10 VDC speed control signal referenced to pin 2 optional 7 Jumper in position for pre set speed 4 Green wire rpm signal referenced to pin 2 optional ...

Page 15: ...uenced by a number of environmental factors such as The type of adsorbent Chamber pressure CO2 production number of persons in the chamber Humidity Temperature Motor speed The service life of a canister filling depends on the above mentioned factors NOTE The O2 and CO2 levels inside the chamber must be continuously monitored The scrubber must always be used in combination with an oxygen make up sy...

Page 16: ...16 Chapter 4 IHCHYTECH COM 4 2 1 PERFORMANCE DIAGRAMS 4 2 1 1 PERFORMANCE AT 50 MSW 4 2 1 2 PERFORMANCE AT 18 MSW ...

Page 17: ... switch off the scrubber motor 1 Remove the canister from the scrubber motor by turning the canister counter clockwise A 2 Place the canister on the bayonet with the cover plate facing upwards B 3 Remove the cover plate by turning it counter clockwise B 4 Replace the adsorbent 5 Mount the cover plate 6 Mount the canister on the scrubber motor 7 The scrubber motor is now ready for use A B ...

Page 18: ...18 Chapter 4 IHCHYTECH COM ...

Page 19: ...plete external speed control 3 80 1018 1E Scrubber complete Aisi pre set speed 3 80 2938 1V Scrubber complete Aisi external speed control 3 80 2938 1E Scrubber motor pre set speed 3 80 1018 2V Scrubber motor external speed control 3 80 1018 2E Canister assembly including canister O ring 3 80 973 Canister O ring 105 00 x 6 00 H 70 00310 Canister Cover plate 3 80 2343 Sofnolime Sodalime CO2 absorben...

Page 20: ...USER MANUAL CO2 SCRUBBER VERSION CS 2019 09 Chapter 5 20 ...

Page 21: ...CAN ISTER 9 D DURATION 9 E ELECTRICAL 13 ELECTRICAL CONNEC TIONS 13 F FAN MOTOR 7 M MAINTENANCE 11 MAINTENANCE 19 MAINTENANCE AND RE PAIR 11 P PERFORMANCE 15 PERFORMANCE DIA GRAMS 16 R REFILL 9 S SAFETY 11 SAFETY MEASURES 11 SAFETY MEASURES 11 SCRUBBER 7 SPARE PARTS 19 SPECIFICATIONS 8 SPEED 13 W WARNING SIGNS 11 ...

Reviews: