0000112315/011017/0 MDB-2/HV 

EN - 8

On the left side of the control panel: main switch (not shown). 

 

Fig. 5.1 

E

D

FAILURE

ALARM

RUNNING

PROGRAM

ON/OFF

RESET

ALARM

A

B

C

Control panel

5.2 

Use

To operate the system, proceed as follows.

•  Make sure that the main switch is on. 

•  Turn the 

PROGRAM ON/OFF

 switch (ref. Fig. 5.1C) to the 

right

4

 to put the system in standby mode. 

The system runs in accordance with the weekly timer settings 

in the PLC

5

Unless service, maintenance or repairs jobs are being done, it 

is recommended to leave the system in standby mode

6

aTTENTiON

Make sure that power supply and compressed air 

supply are available at all times to enable automatic 

filter cleaning. 

5.2.1  System failure

A system failure is indicated by the red control light (ref. Fig. 

5.1A) on the control panel, with an acoustic alarm at the same 

time. In this case, the fan stops running immediately. The 

cause of the problem is indicated on the PLC inside the control 

panel. 

To get to know the problem, proceed as follows. 

aTTENTiON

To keep the message on the PLC, do 

not

 

-

push the button 

rEsEt AlArM

 

-

turn the 

PROGRAM ON/OFF

 button

 

-

turn off the main switch

•  Open the control panel with the supplied key.

•  Check the display of the PLC; it can show two different 

messages: 

 

-

“clogged filter”

 

-

“no air pressure”

•  Push the button 

rEsEt AlArM

 (ref. Fig. 5.1E) to stop the 

buzzer

7

4.

  It concerns a spring-return switch so it returns to its default position.

5.

  The cooling fan continues to run for an additional 5 minutes. 

6.

  During the off times, an offline filter cleaning cycle takes place.

7.

  As long as the cause of the system failure has not been solved, the red control 

light and the acoustic alarm will start again 30 seconds after reset. 

Message “clogged filter” 

The PLC shows this message when the filter pressure has 

reached the preset value (default: 2000 Pa). This means that 

you must replace the filter cartridges. 

•  Refer to section 6.4 for the filter replacement procedure. 

Message “no air pressure”

8

The PLC shows this message when the compressed air 

pressure is absent or insufficient. 

•  Repair the compressed air supply. 

maiNTENaNCE

6.1 

Periodic maintenance

The indicated maintenance intervals can vary depending on 

the specific working and ambient conditions. Therefore, we 

recommend to thoroughly inspect the complete unit once 

every year beside the indicated periodic maintenance. For this 

purpose contact your supplier. 

Component

action

Frequency: 

every X 

months
X=3

X =12

Dustbin

Empty; refer to section 6.2*)

SparkTrap

Empty; refer to section 6.3

X

Compressed air 

regulator

Drain

X

Housing

Make sure that there is no air 

leakage

X

Compressed air 

system

Make sure that the connection is 

correct

X

Make sure that the pressure is 

correct

X

Make sure that the valves and 

membranes are not damaged

X

Filter cartridges

Make sure that the position is 

correct; refer to section 6.4

X

Bolts 

Make sure all bolts are correctly 

tightened 

X

Fan

Make sure that the flexible hose 

at the inlet is not damaged

X

Make sure that the vibration 

dampers are not damaged

X

Make sure that the fan is in 

balance

X

*) During use, the level of contents in the dustbin must be checked 

regularly. The emptying frequency depends on the intensity of use and 

will be a matter of experience. 

In the initial stage, do a check on the level of contents of the dustbin 

two times per week

6.2 

Emptying the dustbin

The dustbin must be emptied regularly. 

Personal protective equipment (PPE)

Wear respiratory protection and protective 

gloves when you empty the dustbin.

To empty the dustbin, proceed as follows.

•  Loosen the quick connect clamp.

•  Use the lifting pin to lower the dustbin. 

•  Pull out the dustbin. 

8.

  A problem with the compressed air supply does not activate the red control 

light and/or the buzzer. You can notice a lack of compressed air by the fact that 

the system stops after 5 minutes of running, while the welding continues. 

Summary of Contents for MDB-2/HV

Page 1: ...movent com EN High vacuum filter system with integrated fan FR Syst me de filtration haute pression avec ventilateur int gr EN Installation and user manual FR Manuel d installation et d utilisation md...

Page 2: ...ehension for people whose first language is not English we have written parts of this manual in Simplified Technical English STE STE is a controlled language originally developed for aerospace industr...

Page 3: ...produit 12 3 Safety 4 3 Instructions de s curit 12 4 Installation 6 4 Installation 14 5 Use 7 5 Utilisation 15 6 Maintenance 8 6 Entretien 16 7 Troubleshooting 9 7 D pannage 17 8 Spare parts 10 8 Pi c...

Page 4: ...l always be willing to help you Make sure you have the following specifications at hand product name serial number You can find these data on the identification plate 1 Introduction 1 1 Identification...

Page 5: ...lief valve The fan housing is provided with an adjustable relief valve to control excess pressure in the system 3 Safety General The manufacturer does not accept any liability for damage to the produc...

Page 6: ...is considered normal use Operating the machine within the limits of its intended use also involves observing the instructions in the user manual Use sufficient climbing gear and safety guards when wo...

Page 7: ...ceed as follows Fig 4 1 Disassemble the top panel A and the side panels B of the fan housing Lift the fan by its two eye bolts C and put it on the filter housing D Attach the fan housing to the filter...

Page 8: ...ccording to the instructions as stated in Fig III on page 20 If applicable modify the weekly timer setting according to the instructions as stated in Fig IV on page 21 4 10 Functioning and setting 4 1...

Page 9: ...that you must replace the filter cartridges Refer to section 6 4 for the filter replacement procedure Message no air pressure 8 The PLC shows this message when the compressed air pressure is absent or...

Page 10: ...e no 0000111622 10 The industrial vacuum cleaner must meet dust class H according to EN 60335 2 69 11 PLC display shows Filter hours 0 scroll menu attention Make sure that the front of the filter cart...

Page 11: ...der 0000111381 DB 80 Dustbin 80 litres incl lifting pin and handles 0000111622 Lid for dustbin DB 80 0324000310 Control light green 24V 0324000320 Control light red 24V A on request HV fan B on reques...

Page 12: ...sp cifiques des travaux d entretien et de r paration qui sortent du cadre de ce manuel veuillez prendre contact avec le fournisseur du produit Ce fournisseur est toujours dispos vous aider Assurez vo...

Page 13: ...s d air comprim avec un intervalle de 30 minutes par impulsion 2 2 3 Soupape casse vide Le bo tier de ventilateur est muni d une soupape casse vide r glable pour contr ler la surpression du syst me 3...

Page 14: ...produit pour vapeurs chaudes d une temp rature d passant les 70 C continuellement projection la flamme Installation L installation du produit est r serv e exclusivement aux techniciens instruits et a...

Page 15: ...9 silencieux r ducteur 200 100 mm coude 90 100 mm tuyau 200 x 50 mm collier de serrage rapide 3 sortie d air SparkTrap cl pour verrouiller d verrouiller l armoire de contr le adh sif polym re 4 3 Posi...

Page 16: ...i de 07h00 17h00 4 Pour changer la langue du menu en fran ais procedez conform ment aux instructions indiqu es la Fig V la page 21 Assurez vous que l horloge en temps r el et la date sont exactes Sino...

Page 17: ...ts clogged filter filtres obstru s no air pressure pas de pression d air Appuyez sur le bouton reset alarm voir Fig 5 1E pour arr ter le ronfleur8 Message clogged filter L automate affiche ce message...

Page 18: ...e de filtration D branchez l air comprim D branchez compl tement l appareil du secteur Desserrez le bouton en toile F et d montez la plaque de couverture E l crou D et la rondelle m tallique C Retirez...

Page 19: ...e Description 0000100297 CART PTFE 10 Cartouche filtrante 0000101900 Electrovanne bobine 24V AC et 3 m de c ble inclus 0000102411 Robinet de vidange pouces 0000102584 Kit de verrouillage pour cartouch...

Page 20: ...25 F 200 G 897 H 200 I 100 J 1477 K 1311 Fig II System overview EN Vue d ensemble du syst me FR C A B EN FR A Duct silencer air outlet Silencieux de conduit sortie d air B SparkTrap Spark arrester par...

Page 21: ...time On Off S W Time On UK API R glage de l heure et de la date FR Pour r gler l heure et la date proc dez comme suit Pressez q pour afficher le temps et la date Pressez ESC S lectionnez D finir Press...

Page 22: ...hacune d elle comprenant trois crans Pour changer les heures de commutation proc dez comme suit Pressez q pour afficher le temps et la date Pressez ESC Select Set Param Pressez q ou p Pressez OK Minut...

Page 23: ...1017 0 MDB 2 HV 22 Fig VI Spare parts EN Pi ces d tach es FR FAILURE ALARM RUNNING RESET ALARM PROGRAM ON OFF A 0000100297 0000102598 0000102666 0000111381 0000111622 0000102675 0324000310 0324000320...

Page 24: ...www plymovent com 0000112315 011017 0 MDB 2 HV...

Reviews: