0000104046/010822/A MDB-Compact PRO
9
-
Use sufficient climbing gear and safety guards when working
on a higher level than 2 metres (6½ ft.) (local restrictions
may apply).
-
Clean the area afterwards.
ATTENTION
Service, maintenance and repairs must be
performed in accordance with directive TRGS 560
and TRGS 528 by authorised, qualified and trained
persons (skilled) using appropriate work practices.
ATTENTION
Before you carry out service, maintenance and/or
repair jobs:
-
fully disconnect the unit from the mains
-
disconnect the compressed air supply
-
de-energize the connected external device
Personal protective equipment (PPE)
Wear respiratory protection and protective
gloves during service, maintenance and
repairs.
WARNING
The industrial vacuum cleaner that you use during
service and maintenance must meet dust class H
according to EN 60335-2-69 or HEPA class
(efficiency ≥99.97% at 0.3 µm).
4
INSTALLATION
4.1
Tools and requirements
You need the following tools and requirements to
install the unit:
-
lifting equipment, e.g. a fork-lift truck or crane
-
lifting gear (refer to paragraph 4.3)
-
basic tools
4.1.1 To be sourced locally
-
Non return valve (refer to paragraph 4.10)
-
Ductwork to connect the unit with the external
device
-
Connection wires (refer to the installation manual of the
ControlPro)
-
Compressed air regulator (in case you have not selected a
CAR-KIT)
-
Compressed air hose Ø 8 mm (L = 3 m/10 ft)
In case of PRECO-N (precoat):
-
inspection hatch (refer to paragraph 4.9)
In case of connection voltage 575V/3ph/60Hz:
-
option: frequency inverter (refer to paragraph 1.4.1)
4.2
Unpacking
The air inlet module, the deflector plates and the
cover plate of the MDB-4/C and MDB-6/C are
supplied separately to allow you to determine the
desired inlet position
4
. The inlet position of the MDB-2/C is
fixed.
Make sure that the product is complete. The package contains:
4.
Either left or top
MDB-2/C
MDB-4/C
MDB-6/C
MDB-Compact (fully assembled)
X
MDB-Compact (semi-assembled)
X
X
-
Cover plate (incl. flange screws)
X
X
-
Air inlet module (incl. flange screws)
X
X
-
Deflector plates
X
X
-
SealApplicator (seal assembly lubricant)
X
X
-
Blinding plug (8)
X
X
Square key (to lock/unlock the dust drawer)
X
X
X
Screw stud (4) + locknut M10 (4)
X
X
X
ControlPro (control equipment)
X
X
X
4.3
Lifting
You can lift the unit by chains, straps or cables.
Refer to paragraph 1.5 for the weight of the units.
ATTENTION
To safely lift the unit, obey the instructions that
follow.
-
Use all four eye bolts.
-
Make sure that the lifting gear is correctly
attached.
-
Lift the unit in fully horizontal position. If not
level: adjust the chain/strap/cable length.
-
Angle of chains/straps/cables: max. 45°.
-
Do not add any additional mass on the unit (e.g.
parts, tools).
-
Do not walk under the suspended load.
-
Use lifting equipment and procedures that comply
with the federal, state or local directives.
• Refer to Fig. III on page 18 for detailed lifting
instructions.
4.4
Positioning
Mounting possibilities:
-
on the floor
-
on a platform
-
on a frame
WARNING
Before you install the unit, make sure that the
foundation or structure is strong enough. Refer to
paragraph 1.5 for the weight of the units.
To safely install the unit, obey the lifting instructions
of paragraph 4.3 and Fig. III on page 18.
• Attach chains, straps or cables to the 4 eye bolts on top of
the unit.
• Use a lifting device to bring the unit to the working area.
• Lift the unit to its final position.
Mounting on the floor
• Make sure that the unit is level.
If necessary, use shims to make the unit level.