0508040020/010111/D FlexHood
EN - 11
The product has been designed to function without problems for
extended periods with minimum maintenance. In order to
guarantee optimal performance level, regular maintenance and
cleaning activities are required which are described in this
chapter. If you observe the necessary caution and carry out the
maintenance at regular intervals, any problems occuring will be
detected and corrected before they lead to a total breakdown.
The indicated maintenance intervals can vary depending on the
specific working and ambient conditions. Therefore it is
recommended to thoroughly inspect the complete product once
every year in addition to the indicated periodic maintenance. For
this purpose contact your supplier.
6.1
Periodic maintenance
The maintenance activities in the table below indicated by (
1
)
can be carried out by the user; other activities are strictly
reserved for well trained and authorised service engineers.
If the modular hood does not function (correctly), follow
cleaning procedure as described under section 6.1. If the
problem still exists, contact your supplier.
The following spare parts are available for the modular hood:
After life of the product, dispose it of in accordance with state or
local regulations.
6
MAINTENANCE
WARNING
Overdue maintenance can cause fire.
ATTENTION!
Always wear face mask and gloves during service and
maintenance work.
Industrial vacuum cleaner used during service and
maintenance should meet dust class H according to
the European standard EN 60335-2-69 or equivalent
international standard.
ATTENTION!
Always wear a respirator and gloves during service
and maintenance work.
Industrial vacuum cleaner used during service and
maintenance should have HEPA rated filtration.
WARNING!
Never stand on top of the
extraction hood.
Frequency
Light use
1)
: Every 3-6 month Every 12 month
Normal use
1)
: Every 3 months Every 9 months
Component
Action
Heavy use
1)
: Every 1-2
months
Every 6 months
Main frame profiles, roof panels
Check outside of the hood and clean it with a non-
aggressive detergent.
X (
1
)
Lighting fixture
Check working light.
X (
1
)
Automatic damper (if any)
Check functionality of the connected automatic damper.
X (
1
)
X
Bottom roof panels and extraction
slots
Check the bottom roof panels and extraction slots of the
hood and clean them thoroughly.
X (
1
)
X
Top roof panels
Clean the inside of the hood and slots by removing top roof
panels.
X
1. Contact your supplier to determine intensity of use.
7
TROUBLESHOOTING
8
SPARE PARTS
Article no.
Description
9750000050
Distance holder (10 pcs)
9750000060
Vertical spacer (10 pcs)
9
DISPOSAL