Functional Description and Specifications RUB SW
1.2 Rear Panel and Connections
DARS IN 2
DARS OUT
8 . . . . . 1
8 . . . . . 1
1 . . . . . 8
1 . . . . . 8
REF/GPO
CLOCK IN 2
8 . . . . . 1
1 . . . . . 8
CLOCK IN 1
DARS IN 1
CLOCK OUT
1
2
3
4
CLOCK OUT 1
BNC
CLOCK OUT 2
BNC
CLOCK OUT 3
BNC
CLOCK OUT 4
BNC
CLOCK IN 1
RJ45 jack
4: GND
5: CLOCK IN 1_1
3: CLOCK IN 1_2
6: GND
1: CLOCK IN 1_3
2: GND
7: CLOCK IN 1_4
8: GND
CLOCK IN 2
RJ45 jack
4: GND
5: CLOCK IN 2_1
3: CLOCK IN 2_2
6: GND
1: CLOCK IN 2_3
2: GND
7: CLOCK IN 2_4
8: GND
CLOCK IN 1/CLOCK IN 2
can be connected straight
(1:1) to the CLOCK OUT
(RJ45) at the RUB GW
module.
DARS IN 1
RJ45 jack
4: Signal 1_1
–
5: Signal 1_1 +
3: Signal 1_2 +
6: Signal 1_2
–
1, 2, 7, 8: GND
DARS IN 2
RJ45 jack
4: Signal 2_1
–
5: Signal 2_1 +
3: Signal 2_2 +
6: Signal 2_2
–
1, 2, 7, 8: GND
DARS IN 1/ DARS IN 2
can be connected straight
(1:1) to the DARS OUT (RJ45)
at the RUB GW module.
REF/GPO
RJ45 jack
1: PPS IN
2: RXD IN
4: GND
5: not connected
3: GPO_1
6: GPO_2
7: GPO_3
8: GPO_4