Functional Description and Specifications RUB SW
4.8
“System“: Identification, Reset, SNMP, Fan Control
Configuration (example shows a screen shot of the PC program tab):
Unit
Name
:
The connected module can get a name. You may enter, change, or verify this
name at this window.
Frame
:
Modules in a network can be uniquely identified by a frame number and the
module’s position within the frame. In a single frame system, you may select
“Single” or “Auto” at th
is set-up. If a system is built-up of more than one
frame, each frame has to receive a unique address (adjusted at the fan
module). If you sel
ect “Auto”, the module will request this frame number
automatically and will show it on the info box. Likewise, it is possible to select
a frame number manually.
Boot
Cold Boot
: Do a cold boot of the module.
Warm Boot
: Do a warm boot of the module.
Info
Displays module’s status information.
SNMP Trap Enable
Activate the “Any Trap” check box to enable the SNMP funct
ionality in general. If not
checked, this module will not send any SNMP traps.
The individual traps can be enabled/disabled by a click on the corresponding check box.
Please notice the chapter ‘
Alarms by SNMP Traps
’
as well.
Thermal Control
At least one module of each frame should have the fan monitoring activated. This enables
the power supply monitoring
–
for power supplies within this frame - as well.