Functional Description and Specifications RUB SW
System
Select the operating mode and some parameters (default values in
bold
characters):
Item
Selection
Description
Changeover
Automatic
Manual
Automatic or manual changeover operating mode.
→
C
hapter ‘
Word Clock Changeover
’
.
Limit Signal
to Signal
Drift
[ms]
1
–
100
(
2
)
SW
monitors the drift between word clock signals. Signal 1 at
CLOCK IN 1
will be compared to signal 1 at
CLOCK IN 2
,
signal 2 at
CLOCK IN 1
with signal 2 at
CLOCK IN 2
, etc. for
all signal pairs.
A “
word clock signal to signal drift
“ error will be indicated if the
drift equals or exceeds this limit.
Allowed range: 1
–
100 ms.
→
C
hapter ‘
Word Clock Monitoring
’
→
‘
Signal to Signal Drift
’
.
Limit Signal
to PPS Drift
[ms]
1
–
100
(
2
)
SW
monitors the drift of each word clock signal compared to
the PPS of the real-time reference.
A “
signal to pps drift
“ error will be indicated if th
e drift equals
or exceeds this limit.
Allowed range: 1
–
100 ms.
→
C
hapter ‘
Word Clock Monitoring
’
→
‘
Signal to PPS Drift
’
.
Reference
Format
Meinberg Std ...
NMEA $GPRMC...
Meinberg Uni ...
Wharton Status ...
SW
expects a PPS and a serial data string from a real-time
reference. The format and protocol of the serial data string
should be selected in accordance with the connected device:
“
Meinberg Std 2400/7e2 + PPS
“
[GPS 10 MHz, GLS 10 MHz]
“
NMEA $GPRMC 4800/8n1 + PPS
“
[GPS35, GPS16, GPS17]
If
“
Meinberg Std 2400/7e2 + PPS
“ has been selected,
SW
automatically accepts the
“
Meinberg GPS
” protocol as well.
→
Chapt
er ‘
Real-Time Reference Monitoring
’
.
Error Reset
Click this button to reset all error counters and status of the module
–
identical to pressing the