Functional Description and Specifications RUB SW
Page 17
2.1.4
Error Reset
The following error indications are self resettable (reset, if no errors are present):
•
The individual
status bits at the status monitor
.
•
The GPO outputs of functions
Signal 1 Failure
,
Signal 2 Failure
,
Word Clock Warning.
A reset of the
System Warning
error is done by one of the keys described below.
The following error indications remain as long as the overall counters have count values > 0:
„
overall errors
“ > 0
„
overall failures
“ > 0
•
LED (ERROR) in the
Switcher Error
function.
•
GPO in the
System Error
function.
•
SNMP trap
System Error
.
•
Lamp (FAIL) in the
Fail
function.
•
GPO in the
System Failure
function.
•
SNMP trap
System Failure
.
A reset of these counters and
–
at the same time
–
a reset of all individual error counters can
be done by:
Keystroke
RUB1 modules, i.e. modules plugged to a 1 RU chassis, offer four programmable keys.
The following functions are provided for a reset:
Function
Description
Recommended
Key
Clear
Resets all error counters to zero.
F1: FAIL
Reset All
Complete reset of error counters and status.
F1: FAIL
It is recommended to assign the „
Reset All
“ function to the FAIL key.
Configuration
Utilizing one of the configuration tools, a complete reset of error counters and status can
be done clicking the “
Error Reset“
button at the
Switcher
page.