background image

 

8.7

 

SUPERVISION 

SUPERVISION  mode  is  applicable  either  in 
regulation  in  STANDARD  and  Fuzzy  Logic 
mode. 
The  controller  switches  into  SUPERVISION 
mode 

automatically 

without 

user’s 

intervention:  -  in  Standard  regulation  mode 
– 

after 

reaching 

the 

boiler 

preset 

temperature, - in Fuzzy Logic steering – after 
exceeding  boiler  preset  temperature  by  5 
degrees C. 

In  SUPERVISION  mode  the  controller 
oversees  the  furnace,  keeping  it  from 
burning  off.  When  activated,  this  mode  can 
minimise the frequency of firing up and then 
burning off. This mode is especially useful in 
hydraulic  systems  without  a  thermal  buffer. 
To do  so, the burner operates with very low 
power, what together with properly adjusted 
parameters  do  not  cause  further  increase  in 
temperature. 

Burner’s 

power 

in 

SUPERVISION  mode    and  other  parameters 
of Supervision are grouped in menu: 

Menu 

→ 

Service  settings 

  Boiler 

settings 

  Supervision 

Parameters of SUPERVISION mode are to be 
set in accordance to burner/boiler producer’s 
recommendations. They should be so chosen 
to  prevent  the  furnace  from  burning  off 
during  boiler’s  pauses  (the  furnace  should 
not  at  the  same  fire  up  to  too  high  a 
temperature, because it will cause too high a 
temperature  of  the  boiler).  Operation  and 
pause  time  of  the  feeder  in  SUPERVISION 
mode is set using following parameters:   

Feeding  time  SUPERVISION

,

  Period  time 

SUPERVISION

  and 

Air  flush  intensity 

SUPERVISION

.   

  

 

The parameters in this mode must 
be so chosen as to make the boiler 
temperature  gradually  decreasing. 
Incorrect  settings  can  cause  boiler 
overheating.  

 
Maximum  time  of  boiler’s  operating  in 
supervision  mode  is  defined  in  parameter 

Supervision  time

.

  If  after  this  time  (in 

Supervision 

mode)

 there  is  no  need  to  restart  the  boiler  boiler 
controller will go in STOP mode. 

 

For setting 

Supervision time

 = 0 the 

controller  omits  SUPERVISION  mode 
and goes directly to STOP.

 

8.8

 

STOP 

In STOP mode the boiler awaits the signal to 
start operation. The following can be a signal 
to start operation: 

 

Decrease  of  preset  boiler  temperature 
below  preset  temperature  diminished  by 
boiler hysteresis  (

Boiler hysteresis

),  

 

By  boiler  operation  configuration  with  the 
buffer  decrease  of  top  buffer  temperature 
below  preset  value  (

Temperature  when 

start buffer feeding

). 

8.9

 

PAUSE 

PAUSE mode is induced manually by pressing 
the  encoder.  Be  sure  to  select  "PAUSE 
MODE". In this mode, the burner is stopped. 
Pumps  are  not  Stoppel.  To  turn  off  the 
"PAUSE  Mode",  press  the  dial  and  select 
"OPERATION". 

 

Note: The "PAUSE MODE" can also 
be 

invoked 

automatically 

by 

opening  a  valve  in  the  boiler 
smoke conduit and the lack of fuel. 
The controller automatically comes 
out of "PAUSE MODE" when causes 
are removed (fill the fuel, close the 
damper). 

8.10

 

HOT WATER SETTINGS 

The  controller  regulates  temperature  of  the 
silo  of  Hot  Water  HW,  providing  that  the 
temperature  sensor  is  connected.  When  the 
sensor  is  disconnected  –  the  information 
about it is displayed in the main window. By 
selecting:  

Menu 

 HUW settings

 →

 HUW Pump 

mode 

the user is able to: 

 

Deactivate feeding the silo, parameter 

Deactivated

 

Setting  HW  priority,  by  parameter 

Priority

 

– 

then 

CH 

pump 

is 

deactivated  to  feed  the  HW  boiler 
quicker, 

 

Set simultaneous operation of CH and 

HW  pump  with  the  parameter 

No 

priority

,

 

 

Activate function 

Summer

Summary of Contents for ecoMAX850P1-R

Page 1: ...ns available in additional module B functions available in additional module C MX 03 room panel ecoSTER200 non standard option USER MANUAL FOR MAINTENANCE AND INSTALLATION EDITION 1 0 APPLIES FOR HARD...

Page 2: ......

Page 3: ...TALLATION REQUIREMENTS 23 12 3 INSTALLATION 24 12 4 ELECTRIC CIRCUIT CONNECTION 24 12 5 SAFETY CONNECTIONS 26 12 6 ELECTRIC SCHEME 26 12 7 TEMPERATURE SENSORS CONNECTION 28 12 8 WEATHER SENSORS CONNEC...

Page 4: ......

Page 5: ...the feeder etc The controller is for boiler producers The boiler producer before its use should check if the cooperation between the controller and the boiler is correct and is not dangerous The cont...

Page 6: ...entation The user s manual of the controller is divided into two parts for the user and for the installer However in both parts vital information concerning safety is included That is why the user sho...

Page 7: ...USER MANUAL OF THE CONTROLLER ecoMAX850P1 R...

Page 8: ...MER Deactv temperature SUMMER Mixer settings 1 2 3 4 5 Preset mixer temperature Mixer room thermostat Weather control mixer Heating curve Mixer Curve shift Room temperatur factor Night time decrease B...

Page 9: ...re decrease due to activated time spans C Boiler preset temperature during loading the hot water boiler HW M Boiler preset temperature increase from mixer circulation P weather control switch on for b...

Page 10: ...ing sure that fuel is in the silo and the hatch is closed the boiler can be switched on 8 4 BOILER TEMPERATURE SETTING The preset boiler temperature and preset circuits temperature can be set in the m...

Page 11: ...reset temperature i e when the boiler sensor reaches Preset boiler temperature Max Min hysteresis Pic 6 Output modulation STANDARD mode where Tzk preset boiler temperature H Max Min Max Min hysteresis...

Page 12: ...ause boiler overheating Maximum time of boiler s operating in supervision mode is defined in parameter Supervision time If after this time in Supervision mode there is no need to restart the boiler bo...

Page 13: ...periodically make HW silo warm up to 70 degrees C It is done to remove bacterial flora It is absolutely important to inform all the inmates about activating the disinfection function There is a dange...

Page 14: ...be necessary to adjust heating curve movement In this configuration room thermostat ecoSTER is able to reduce temperature of heating cycle by a constant value when preset temperature in a room will be...

Page 15: ...e parallel shift and choose higher heating curve Buildings which are poorly isolated require setting heating curve with higher values and for better isolated buildings heating curve will have lower va...

Page 16: ...indow of the display Pic 11 Signalling time periods 8 18 CIRCULAR PUMP CONTROL Settings are in MENU Night time decrease Circular pump and Menu Service settings CH and HUW settings Settings of time con...

Page 17: ...el level reaches expected minimum parameter value should be set this way Menu Boiler settings Fuel level Fuel level calibration Fuel level 0 8 20 COOPERATION WITH ADDITIONAL FEEDER After connecting ad...

Page 18: ......

Page 19: ...19 USER MANUAL OF CONTROLLER INSTALLATION AND SERVICE SETTINGS ecoMAX850P1 R...

Page 20: ...t is necessary to isolate it thermically from surroundings and improve thermal contact with pipe Preset silo temperature must be set so high to ensure thermal power for mixer cycle when at the same ti...

Page 21: ...boiler settings Min preset boiler temperature 75 C menu service settings boiler settings CH pump activating temperature 55 C menu service settings CH and HUW settings Activating operation buffer servi...

Page 22: ...active menu service settings buffer settings Buffer loading start temperature 50 menu service settings buffer settings Buffer loading stop temperature 75 menu service settings buffer settings Mixer se...

Page 23: ...rays Temperature of storage and transport should be within scope 15 65 degrees C During transport the controller can not be exposed to vibrations bigger than typical for transport of boilers 12 CONTRO...

Page 24: ...rface 12 4 ELECTRIC CIRCUIT CONNECTION The controller is adapted to current 230V 50Hz Features of installation 3 way with protecting wire made according with valid law Attention After deactivating the...

Page 25: ...tly screwed by pulling wire Length of isolation of external tire of wires should be minimal maximum 60mm If it is necessary to longer isolate the wire tire they should be connected with each other or...

Page 26: ...al operation of the boiler T7 mixer temperature sensor FS fuel level sensor CS hatch opening sensor P controlling panel ecoSTER200 room panel with room thermostat function replacing TB or TM D D conne...

Page 27: ...ve 2 or 4 CT4 T2 temperature sensor for mixing valve 3 or 5 CT4 T3 upper buffer temperature sensor T4 lower buffer sensor CT4 T room thermostat B extension module C extension module 230V power cord PM...

Page 28: ...res of the sensors are resistant to temperature not exceeding 100 degrees C 12 8 WEATHER SENSORS CONNECTION The controller cooperates solely with weather sensor type CT4 P The sensor should be install...

Page 29: ...own on Pic 16 12 12 BOILER ROOM THERMOSTAT CONNECTION Room thermostat for boiler circuit can switch off the burner operation or switch off the CH boiler pump In order to thermostat switch off boiler o...

Page 30: ...alarms compatible with alarm signal codes causes activation of additional boiler When pellet boiler is fired up and its temperature exceedes preset value i e 25 degrees C then controller switches off...

Page 31: ...where 1 controller 2 external alarm device 3 transmitter Then in order to operate correctly set proper code for active alarms signal in menu Menu Service settings Boiler settings Alarms Choosing valu...

Page 32: ...cumentation Do not confuse opening direction with closing direction Connect electrical power to the controller and switch it into STAND BY mode Check if wires for mixer opening and closing are not swa...

Page 33: ...which has following functions Room thermostat controls up to 3 thermostats Controlling panel for the boiler Alarm signal Fuel level indicator 4 way connection Connect accordingly to point 12 6 2 way c...

Page 34: ...eed time Cycle time Blow in output Delay Min airflow output Fuel detection time Additional feeder operation time Clamps 28 29 delay Boiler settings Thermostat selection Min boiler temperature Max Boil...

Page 35: ...ime Blow in for Min output kW Blow in output for minimum boiler output 30 Feeder efficiency Feeder fuel efficiency in kg h Energy density Fuel calorific in kWh kg Tank capacity Fuel silo capacity for...

Page 36: ...n Options to choose from Deactivated deactivates room thermostat influence on boiler operation Universal activates room thermostat for boiler ecoSTER200 T1 option available after connecting room panel...

Page 37: ...r in the silo can heat up to dangerous temperature It is necessary to use additional protection in the form of thermostatic valves Boiler Increase byHUW and Mixer Parameter determines how high the boi...

Page 38: ...is option is normally used to control floor heating pump in situation when it cooperates with thermostatic valve without servomotor By such action is not recommended It is recommended to use standard...

Page 39: ...u Setting parameter determining value of temperature dead zone for mixer controlling circuit The controller regulates mixer in such a way to keep the temperature of mixer cycle equal to preset value H...

Page 40: ...t pipe is not beneficial because it may cause delay in detecting boiler overheating state Pic 26 Alarm of boiler overheating view 15 2 BOILER TEMP SENSOR FAILURE Alarm appears by boiler sensor damage...

Page 41: ...not protect the installation against freezing 16 3 PUMP ANTI STANDSTILL FUNCTION The controller does the function of CH HW and Mixer pumps protection against getting stale 16 4 NETWORK FUSE REPLACEMEN...

Page 42: ...in fumes It is not recommended to change these parameters if regulation time and stability of keeping preset amount of air on required level Periodical calibration of Lambda sond readings can be nece...

Page 43: ...osition it should be unlocked by untwisting the cover and twisting the button according to documentation of boiler producer Check the fan and replace it if necessary 5 Additional ffeder is not working...

Page 44: ...parameters are those related to Firing up Operation and Burning off The controller is able to change the default settings depending on power and type of the burner Default settings for given boilers...

Page 45: ......

Page 46: ......

Page 47: ......

Page 48: ...Ignatki 27a 16 001 Kleosin Poland tel 48 85 749 70 00 fax 48 85 749 70 14 plum plum pl www pum pl www plumelectronics eu...

Reviews: