24
8.5.
Read Menu
1.
Choose the desired button using the ‘
up
’ and/or ‘
down
’ buttons
2.
Press ‘
Enter
’ shortly.
3.
You are now in the chosen parameter.
4.
Press ‘
Enter
’ to go back to Service Menu.
The following parameters can be read in the Read Menu:
Number
Parameter
Explanation
1
Cycle Counter M1
Cycle counter Motor 1 (main drive)
2
Cycle Counter M2
Cycle counter Motor 2 (Spreader Bar drive)
3
Act Battery [mV]
Current Battery voltage
4
Act Cur M1 [mA]
Current power consumption Motor 1
5
Act Cur M2 [mA]
Current power consumption Motor 2
6
Software Version
Software version
7
Program Date
Programming date
The display of the Programming Box shows the following:
R e a d
M e n u
P
L
S
1
.
C y
c
l
e
C o u N t
e
r
M 1
?
?
?
?
?
?
?
?
?
???????? = the value of the parameter, 36 for example. This means that M1 has undergone 36 cycles.
8.6.
Edit Menu
1.
Choose the desired parameter with the buttons
‘Up’
and
‘Down’.
2.
Change the parameter by pressing the buttons
‘Minus’
and
‘Plus’
.
3.
By holding ‘
Enter
’ for 2 seconds, the settings will be saved, and you return to Operation Mode.
You can change the following parameters in the Edit Menu:
Number
Parameter
Explanation
1
Bedroom mode
Bedroom mode
2
MaxCurM1 CW [mA]
Maximum power consumption Motor 1 (up)
3
MaxCurM1 CCW [mA]
Maximum power consumption Motor 1 (down)
4
MaxCurM2 CW [mA]
Maximum power consumption Motor 2 (left)
5
MaxCurM2 CCW [mA]
Maximum power consumption Motor 2 (Right)
6
Battery Save Mode
Power saving mode
7
Bedroom mode
Bedroom mode
The display of the Programming Box shows the following with in the lowest rule the parameter:
E d
i
t
M e n u
P
L
S
1
.
B e d
r
o o m
M o d e
O N
Never change the Maximum power consumption of the Motors when there is no need! PLS
programmed the maximum current in the PCB for that specific Ceiling Hoist. Too much current
(power) results in lifting more weight by the care recipient with can be fatal for the construction.