TR-3-26
4 August 2009
3.2.11 STOP GATE MOTOR M3 & SENSOR Q7
AREA C
Removal
1. Remove Stop gate carriage (
3.2.10).
2. Remove nut [A] ( x1).
3. Remove Crank arm [B].
4. Remove screws [C] holding the motor ( x4).
5. Loosen set screw [D] ( x1).
Replacement
1. Mount the Crank pulley [E] without tightening the set screw [D] ( x1).
2. Mount motor with screws [C] ( x4).
3. Mount Crank arm [B].
4. Tightening nut [A] ( x1).
NOTE: Make sure play for Crank arm [B] is maintained.
5. Position the Crank pulley [E] so it is aligned with Crank arm [B].
6. Tighten set screw [D] ( x1) on the flat of the shaft..
7. Reinstall Stop gate carriage (
3.2.10).
[A]
[D]
[C]
[B]
[E]