NOTES:
• If using a non-Leviton Programmer/Remote,
refer to the Programmer/Remote instruction
sheet for including a device.
A)
If using a Leviton Z-Wave
TM
Programmer/
Remote, Cat. No. RZCPG, press the Menu
button and scroll down to System Setup.
Press the center button to select System
Setup Menu. Press the center button to select
Network.
Scene Capable Plug-In Appliance Module
Cat. No. RZP15
Incandescent: 1800W Fluorescent: 1800VA Resistive: 15A Motor: 1/2HP
Rated: 120VAC, 60Hz
INSTAllATION INSTRuCTIONS
DI-000-RZP15-00C
INTRODuCTION
Leviton’s Vizia
TM
RF components are designed
to communicate with each other via Radio
Frequency (RF) to provide remote control
of your lighting. Using RF technology allows
Leviton to provide the greatest signal integrity
possible. Each module in Leviton’s Vizia
TM
RF component line is a Z-Wave
TM
enabled
device. In a Z-Wave
TM
network, each device is
designed to act as a router. These routers will
re-transmit the RF signal from one device to
another until the intended device is reached.
This ensures that the signal is received by its
intended device by routing the signal around
obstacles and radio dead spots. The Scene
Capable Plug-in Lamp Dimming Module
is compatible with any Z-Wave™ enabled
network, regardless of the manufacturer and
can also be used with other devices displaying
the Z-Wave™ logo.
CAuTION:
Remember to exercise good common sense
when using the Timer features of your remote,
especially when scheduling unattended
devices. There can be some unexpected
consequences if not used with care. For
example, an empty coffee pot can be remotely
turned on. If that should happen, your coffee
pot could be damaged from overheating. If an
electric heater is turned on by remote control
while clothing is draped over it, a fire could
result.
DO NOT uSE
the remote for the control
of high power heating appliances such as
portable heaters. This device will not control
lighting that is used with electronic low-voltage
and high frequency power supply transformers,
nor high pressure discharge lamps (HID
lighting). This includes mercury-vapor, sodium
vapor and metal halide lamps.
DO NOT
change
location after unit is enrolled in Z-wave network.
Including Scene Capable
Plug-In Appliance Module
into Z-Wave
TM
Network:
Step 3
Attaching Scene Capable
Plug-In Appliance Module to
Wall Receptacle:
Step 2
• Plug the Scene Capable Plug-in Appliance
Module into wall receptacle. Verify that
receptacle is live. If controlled by a wall switch,
the switch
must be kept ON
at all times.
Attaching load to Scene
Capable Plug-In Appliance
Module:
Step 1
NOTE:
In order to use your Vizia
TM
Scene
Capable Plug-In Appliance Module in a Z-Wave
TM
network, it must be included in the network using
a Primary Programmer/Remote, such as Leviton’s
Cat. No. RZCPG. Before including your module,
please refer to the Primary Programmer/Remote
instruction sheet for complete information.
Refer
to Step 3 for further details
.
• Locate load to be controlled by Scene Capable
Plug-In Appliance Module and ensure it is
fully operational. Attach load plug into module
receptacle noting proper polarity of blades.
NOTE:
Use check boxes when Steps are
completed.
INSTAllING YOuR APPlIANCE MODulE
B)
While standing close to the module
(approximately 2-5 ft.), press the center
button to <Include> device in the network.
NOTE:
Only one device may be included
at a time.
DO NOT
put multiple devices into
the Inclusion mode at any time.
C)
While the Programmer/Remote is in the
Inclusion mode and the LED is ON on
the Scene Capable Plug-In Appliance
Module, press the ON/OFF button on the
module. The Programmer/Remote will verify
inclusion and the LED will turn OFF on the
Scene Capable Plug-In Appliance Module.
If the Scene Capable Plug-In Appliance
Module is flashing Amber while in the
Inclusion mode, the Programmer/Remote is
still trying to communicate with the Scene
Capable Plug-In Appliance Module. Wait
until the device stops flashing, then press
ON/OFF button.
NOTE:
If the LED on the Scene Capable
Plug-In Appliance Module turns solid
Red while including, there has been
a communication error.
Refer to
Troubleshooting section.
D)
The Primary Programmer/Remote will
assign a node ID number (Name) for this
module.
NOTE:
This ID number (Name) will be
stored in the controller to be used for future
reference.
NOTE:
You may name or edit the node of
this device at this time.
E)
The module is now installed in the
network
.
NOTE:
If the module has been successfully
included in the network and the user tries to
include it again without first excluding it from
the network, the module
will retain the first node ID
it had received and ignore
the second.
• Soft fade ON/OFF
• Scene capable
• ON/OFF LED
• Two way communication
• RF reliability
• Ease of installation – No new wiring
• Compatible with other Z-Wave™ enabled
devices
FEATuRES
Step 2 cont’d
Step 3 cont’d
Programming and
ON/OFF Button
1
ON
2
ON
3
ON
4
ON
OFF
OFF
OFF
OFF
Programmer/Remote
Cat. No. RZCPG
Center Button
Menu Button
Compatible with
enabled products!
TM
WARNINGS AND CAuTIONS:
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualified electrician.
WARNINGS AND CAuTIONS:
• Unplug unit when servicing fixture or changing bulbs.
• Save this instruction sheet. It contains important technical data along with testing and
troubleshooting information which will be useful after installation is complete.