background image

NOTES:

•  If using a non-Leviton Programmer/Remote, 

refer to the Programmer/Remote instruction 

sheet for including a device.

A)

 If using a Leviton Z-Wave

TM

 Programmer/

Remote, Cat. No. RZCPG, press the Menu 

button and scroll down to System Setup. 

Press the center button to select System 

Setup Menu. Press the center button to select 

Network.

Scene Capable Plug-In Appliance Module

Cat. No. RZP15

Incandescent: 1800W      Fluorescent: 1800VA     Resistive: 15A     Motor: 1/2HP

Rated: 120VAC, 60Hz

INSTAllATION INSTRuCTIONS

DI-000-RZP15-00C

 INTRODuCTION

Leviton’s Vizia

TM

 RF components are designed 

to communicate with each other via Radio 

Frequency (RF) to provide remote control 

of your lighting. Using RF technology allows 

Leviton to provide the greatest signal integrity 

possible. Each module in Leviton’s Vizia

TM

 

RF component line is a Z-Wave

TM

 enabled 

device. In a Z-Wave

TM

 network, each device is 

designed to act as a router. These routers will 

re-transmit the RF signal from one device to 

another until the intended device is reached. 

This ensures that the signal is received by its 

intended device by routing the signal around 

obstacles and radio dead spots. The Scene 

Capable Plug-in Lamp Dimming Module 

is compatible with any Z-Wave™ enabled 

network, regardless of the manufacturer and 

can also be used with other devices displaying 

the Z-Wave™ logo. 

CAuTION:

Remember to exercise good common sense 

when using the Timer features of your remote, 

especially when scheduling unattended 

devices. There can be some unexpected 

consequences if not used with care. For 

example, an empty coffee pot can be remotely 

turned on. If that should happen, your coffee 

pot could be damaged from overheating. If an 

electric heater is turned on by remote control 

while clothing is draped over it, a fire could 

result. 

DO NOT uSE

 the remote for the control 

of high power heating appliances such as 

portable heaters. This device will not control 

lighting that is used with electronic low-voltage 

and high frequency power supply transformers, 

nor high pressure discharge lamps (HID 

lighting). This includes mercury-vapor, sodium 

vapor and metal halide lamps. 

DO NOT 

change 

location after unit is enrolled in Z-wave network.

Including Scene Capable 

Plug-In Appliance Module 

into Z-Wave

TM

 Network:

 

Step 3

Attaching Scene Capable 

Plug-In Appliance Module to 

Wall Receptacle:

 

Step 2

•  Plug the Scene Capable Plug-in Appliance 

Module into wall receptacle. Verify that 

receptacle is live. If controlled by a wall switch, 

the switch 

must be kept ON

 at all times.

Attaching load to Scene 

Capable Plug-In Appliance 

Module:

 

Step 1

NOTE:

 In order to use your Vizia

TM

 Scene 

Capable Plug-In Appliance Module in a Z-Wave

TM

 

network, it must be included in the network using 

a Primary Programmer/Remote, such as Leviton’s 

Cat. No. RZCPG. Before including your module, 

please refer to the Primary Programmer/Remote 

instruction sheet for complete information. 

Refer 

to Step 3 for further details

.

•  Locate load to be controlled by Scene Capable 

Plug-In Appliance Module and ensure it is 

fully operational. Attach load plug into module 

receptacle noting proper polarity of blades.

NOTE:

 Use check boxes           when Steps are 

completed.

INSTAllING YOuR APPlIANCE MODulE

B)

 While standing close to the module 

(approximately 2-5 ft.), press the center 

button to <Include> device in the network.

 

NOTE:

 Only one device may be included 

at a time. 

DO NOT

 put multiple devices into 

the Inclusion mode at any time.

C)

 While the Programmer/Remote is in the 

Inclusion mode and the LED is ON on 

the Scene Capable Plug-In Appliance 

Module, press the ON/OFF button on the 

module. The Programmer/Remote will verify 

inclusion and the LED will turn OFF on the 

Scene Capable Plug-In Appliance Module.

  If the Scene Capable Plug-In Appliance 

Module is flashing Amber while in the 

Inclusion mode, the Programmer/Remote is 

still trying to communicate with the Scene 

Capable Plug-In Appliance Module. Wait 

until the device stops flashing, then press 

ON/OFF button.

 

NOTE:

 If the LED on the Scene Capable 

Plug-In Appliance Module turns solid 

Red while including, there has been 

a communication error. 

Refer to 

Troubleshooting section. 

D)

 The Primary Programmer/Remote will 

assign a node ID number (Name) for this 

module.

 

NOTE:

 This ID number (Name) will be 

stored in the controller to be used for future 

reference.

 

NOTE:

 You may name or edit the node of 

this device at this time.  

E)

 

The module is now installed in the 

network

.

NOTE:

 If the module has been successfully 

included in the network and the user tries to 

include it again without first excluding it from 

the network, the module 

will retain the first node ID 

it had received and ignore 

the second.

•   Soft fade ON/OFF 

•   Scene capable

•   ON/OFF LED 

•   Two way communication 

•   RF reliability 

•   Ease of installation – No new wiring

•   Compatible with other Z-Wave™ enabled 

devices

 FEATuRES

 

Step 2 cont’d

 

Step 3 cont’d

Programming and 

ON/OFF Button

ON

ON

ON

ON

OFF

OFF

OFF

OFF

Programmer/Remote

Cat. No. RZCPG

Center Button

Menu Button

Compatible with

enabled products!

TM

WARNINGS AND CAuTIONS:

•  To be installed and/or used in accordance with appropriate electrical codes and regulations.
•  If you are unsure about any part of these instructions, consult a qualified electrician.

WARNINGS AND CAuTIONS:

•  Unplug unit when servicing fixture or changing bulbs.
•  Save this instruction sheet. It contains important technical data along with testing and 

troubleshooting information which will be useful after installation is complete.