Issued/Revised:
5FT DOUBLE SLIDE 02-07-5065
u
PLAY TODAY
800.458.5872
www.ultraplay.com
6
8
4/28/2017
= INSTALLATION DETAIL
FINISHED ASSEMBLY
MAINTENANCE PROCEDURE:
Periodically check hardware for tightness, and tighten as necessary. Always check all parts for breakage or wear, and immediately
put equipment out of service until any faulty parts found are repaired or replaced. Also Check all metal parts for rust, paint loss and
touch-up if necessary with paint. Check for welded areas and verify integrity. Check periodically resilient surfacing for appropriate
depth and remove extraneous materials that could cause injury, infection, or disease. Maintain detailed installation, inspection,
maintenance, and repair records for each public-use playground equipment.
7. Insert Double Slide Hood into top holes in Double Slide, and attach Clamps Double Slide to Uprights using M8 x 25mm B.H.C.S. Bolt and
M8 Lock Nut. See Detail 073. (Do not install Clamp Rivet until entire unit is assembled.)
8. Attach Extension Tube to Footer Plate using M10 x 35mm B.H.C.S. Bolt and M10 Lock Nut. See Detail 036.
9. Insert Extension Tube into Bottom Bracket and secure with M10 x 35mm B.H.C.S. Bolt and M10 Lock Nut. See Detail 077.
10. Attach Footer to Center Support Post using M10 x 35mm B.H.C.S. and M10 Lock Nut. See Detail 028.
11. Plumb and level entire assembly before tightening all fasteners. Note: Apply Loctite to threads of Bolt to prevent from loosening.
EXIT HEIGHT CHART
STANDARD
EXIT HEIGHT from SURFACING
ASTM
7" TO 15"
CSA
175mm TO 380mm
EN
350mm OR LESS
COMPONENTS SHOWN IN
HIDDEN LINES ARE SOLD SEPARATELY
DOUBLE
SLIDEHOOD
(02-07-0174)
CLAMP DOUBLE SLIDE
(02-07-0193)
5FT DOUBLE
STRAIGHT SLIDE
(02-07-0173)
DOUBLE SLIDE
DECK FILLER
(02-07-0192)
072
031
UNDERNEATH
UNDERNEATH
MID SUPPORT BRACKET
(02-07-0191)
UNDERNEATH
1" FOOTER
(02-07-0043)
UNDERNEATH
076
FOOTER PLATE
(02-07-0046)
UNDERNEATH
EXTENSION TUBE
(02-07-0202)
UNDERNEATH
BOTTOM BRACKET
(02-07-0190)
UNDERNEATH
036
075
077
UNDERNEATH
028
REFER TO EXIT
HEIGHT CHART
IMPORTANT:
TO ENSURE PROPER WATER
DRAINAGE AT SLIDE EXIT. THE SLOPE OF
THE EXIT REGION SHALL BE BETWEEN
0 AND -4° AS MEASURED FROM A PLANE
PARALLEL TO THE UNDERLYING SURFACE
Summary of Contents for ultraPLAY uPLAY TODAY MADDIE'S CHASE UPLAY-006-N
Page 2: ......
Page 9: ......
Page 10: ......
Page 11: ......
Page 18: ...Issued Revised TOOLS REQUIRED uPLAY TODAY 800 458 5872 www ultraplay com 16 4 12 2018 ...
Page 72: ...02 07 5065 ENGINEERING REVISIONS for A RWR UPDATED SLIDE EXIT NOTE 04 28 17 ...