11 Disposal
Note
DIEHL AKO takes back PLATINUM inverters completely.
It is possible to dispose of PLATINUM inverter through communal
disposal of electrical appliances.
12 Troubleshooting
12.1 Table of events
To isolate the error, have the following information ready when calling
Service:
Î
displayed error number (No.)
Î
serial number of the inverter (see 7.7 Information)
Â
Dispose of packaging and consumed parts
according to the rules and regulations
applicable in the country where the device was
installed.
Â
Do not dispose of the PLATINUM inverter in the
household waste.
No.
Operating status
Measure
Fatal errors
90
AC voltage too high
Separate inverter from mains.
Check connection of AC plug.
91
DC voltage too high
Separate inverter from mains.
Separate inverter from DC terminal.
Check module interconnection.
92
Polarity of DC connection
reversed
Check DC connection.
93
Insulation error between PV+ or
PV- and earth
Check insulation of PV modules.
Check insulation of PV wiring.
94
Fatal
system error
Disconnect AC connector from inverter input. Call Service.
Provide the service with the error code if required.
95
Fatal
system error
Call Service.
Provide the service with the error code if required.