10 Placing out of operation
10.1 Dismounting
To disconnect the inverter:
Â
Switch off the main power supply (fuse).
Â
Remove cable from AC terminal.
Â
Set DC disconnector to 0 and pull plug connector of input voltage
(DC side).
Â
Disconnect remaining connectors as required.
Danger
Danger to life do to DC and AC high voltage!
Â
Wear insulating protective clothing and face
protection.
Â
Have inverters uninstalled by qualified specialists
only.
The qualified specialist personnel requires a license
from the relevant energy suppliers.
Â
Switch off the main power supply (fuse).
Â
Set switch knob of DC connector to 0.
Â
Condensers require up to 30 min to discharge.
Do not touch connectors (DC/AC) for at least 5
minutes after switching off.
Â
Ensure that the DC cables are de-energized.
It is possible that DC cables carry dangerously high
voltages even if the DC disconnector is switched off.
In case of a PLATINUM inverter without DC disconnector
and AC cable:
Â
Disconnect in the following order:
1. Remove cable from terminal strip on AC side.
2. Pull DC plug.
Danger
Danger to life due to inverter dropping from the wall!
Â
Use mounting elements appropriate for the mounting
wall and the weight of the inverter unit.
During mounting and dismounting:
Â
Wear protective shoes.
Â
Ensure a stable position.