Fig. 4A - IN Menu
Fig. 5A - OUT Menu
4
5
4.0 IN Menu
IN
The IN screen gives a running total of Amp hours
(Ah), or energy, that has been input during the
day (since midnight). This total is the sum of Solar
Ah collected and any external Ah input that was
measured using an optional shunt and PLS2.
IN/INT
From the IN screen, a long push displays INT
(Internal Ah IN). This is the running total of Ah
collected from the solar over the day (since
midnight). A long push will clear the INT running
total.
IN/EXT
From the INT screen, a short push displays EXT
(External Ah IN). This is the running total of
external Ah input and measured using an optional
shunt and PLS2. A long push will clear the EXT
running total.
5.0 OUT Menu
OUT
The OUT screen gives a running total of Amp
hours (Ah), or energy, that has been used during
the day (since midnight). This total is the sum of
Ah used by equipment connected to the LOAD
terminal and any external Ah measured using an
optional shunt and PLS2.
OUT/INT
From the OUT screen, a long push displays INT
(Internal Ah OUT). This is the running total of Ah
used by equipment connected to the regulator’s
LOAD- terminal. A long push will clear the INT
running total.
OUT/EXT
From the INT screen, a short push displays EXT
(External Ah OUT). This is the running total of
external Ah used and measured using an optional
shunt and PLS2. A long push will clear the EXT
running total.