Rev 6.3.0 12.09.16
PL Reference Manual
23
SET/MODE/LSET
# Function
Terminal is:
0 Low battery
disconnect
on when function
wants to disconnect
battery
1 Low battery
disconnect
(default)
off when function
wants to disconnect
battery
2 Generator
control
on when function
wants to run generator
3 Generator
control
off when function
wants to run generator
4 Event control
on when event is on
5 Event control
off when event is on
6 2nd battery
charge control
on when battery 2
should charge
7 2nd battery
charge control
off when battery 2
should charge
8 Alarm output
off when battery
voltage < alarm setting
9 Alarm output
on when battery
voltage < alarm setting
10 Diversion control
(Must be selected
for PWM control
of the LOAD-
terminal)*
off when function
wants to disconnect
the Diversion load
(ON for regulation)
11 Diversion control
(PWM must not
be set to 2 or 3)*
on when function
wants to disconnect
Diversion load (OFF
for regulation)
* Don’t use LSET=11 with PWM.
SET/MODE/GSET
# Function
Terminal is:
0
Low battery
disconnect
on when function wants
to disconnect battery
1
Low battery
disconnect
off when function wants
to disconnect battery
2
Generator
control (default)
on when function wants
to run generator
3
Generator
control
off when function wants
to run generator
4
Event control
on when event is on
5
Event control
off when event is on
6
2nd battery
charge control
on when battery 2
should charge
7
2nd battery
charge control
off when battery 2
should charge
8
Alarm output
off when battery voltage
< alarm setting
9
Alarm output
on when battery voltage
< alarm setting
10 Diversion
control**
off when function wants
to disconnect Diversion
load (ON for regulation)
11 Diversion
control**
on when function wants
to disconnect Diversion
load (OFF for regulation)
** Note: PWM not available on G Terminal
7
The LSET setting allows you to choose which
function controls the LOAD- terminal, and
whether the terminal is on or off when the
function is active. The GSET setting allows you
to choose which function controls the general
purpose “G” terminal (under the cover), and
whether it is on or off when the function is
active.