User’s Manual of IGS-20040MT
Priority Code Point value used for PTP frames.
PCP
Clock current Data Set
Object
Description
Steps Removed : It is the number of PTP clocks traversed from the grandmaster
to the local slave clock.
stpRm
Time difference between the master clock and the local slave clock, measured in
ns.
Offset from master
The mean propagation time for the link between the master and the local slave
Mean Path Delay
Clock Parent Data Set
Object
Description
Clock identity for the parent clock, if the local clock is not a slave, the value is the
clocks own id.
Parent Port Identity
Port Id for the parent master port
Port
Parents Stats (always false).
P Stat
It is observed parent offset scaled log variance
Var
Observed Parent Clock Phase Change Rate. i.e. the slave clocks rate offset
compared to the master. (unit = ns per s).
Change Rate
Grand Master Identity
Clock identity for the grand master clock, if the local clock is not a slave, the
value is the clocks own id.
The clock quality announced by the grand master (See description of Clock
Default DataSet:Clock Quality)
Grand Master Clock
Quality
Clock priority 1 announced by the grand master
Pri1
Clock priority 2 announced by the grand master
Pri2
Servo Parameters
Object
Description
If true then Offset From Master, MeanPathDelay and clockAdjustment are logged
on the debug terminal
Display
If true the P part of the algorithm is included
P-enable
If true the I part of the algorithm is included
I-enable
D-enable
If true the D part of the algorithm is included