User’s Manual of ICS-10x
-52-
4.5 Serial Port Configuration
he screen in Figure 4-52 appears.
The page shows the converter’s serial Port configuration. T
Figure 4-52
Serial Port Configuration page screen
The page includes the following fields:
From the drop-down menu, select the serial port mode:
Mode
RS-232
RS-422
RS-485
Baudrate
serial device, such as a modem, must agree on a speed or
The unit and attached
baud rate to use for the serial connection, Valid baud rates.
It’s in the range of
300bps
to
921600bps
.
Character Bits
tted data package. The allowed value
is
5
,
6
,
7
,
8
Indicates the number of the bits in a transmi
The default is
“8”.
Parity Type
y type. The default value is
“none”
.
Checks for the parit
Stop Bit
The stop bit follows the data and parity bits in serial communication. It indicates
the end of transmission. The default is
“1”.
Hardware Flow Control
vices in a network to ensure it is
processed efficiently. Too much data arriving before a device is prepared to
Flow control manages data flow between de
manage it causes lost or retransmitted data. The default value is
“none”
.