User’s Manual of ICS-10x
-49-
Example: Two ICS-10x with Pair Connection mode
One be configured as
Pair Connection – Local
(Master)
The other one be configured as
Pair Connection – Remote
(Slave)
Via the RS-485 interface, the external scanners, speed dome cameras and PTZ receivers can be controlled by the
keyboard which provides upward, downward, leftward, rightward, clockwise and counterclockwise with the joystick. In this
case, we use two ICS-10x to extend the distance between an IP surveillance PT Camera and a Control keyboard. Both of
the two equipments are implemented with RS-485 interface.
The two of the ICS-10x master and slave with below settings:
ICS-10x Master
Connect to
Control Keyboard
IP Address / Subnet Mask
192.168.0.100 / 255.255.255.0
Operation Mode
Mode: Pair Connection – Local
TCP Port Number : 1024
Serial Mode:
RS-485
Baudrare:
9600
Character Bits:
8
Parity Type :
none
Stop Bit :
1
Serial Port Configuration
Hardware Flow Control:
none
ICS-10x Slave
Connect to
Speed Dome Camera, PTZ or Scanner
IP Address / Subnet Mask
192.168.0.101 / 255.255.255.0
Mode:
Pair Connection – Remote
Remote Host IP Address :
192.168.0.100
Operation Mode
Remote Host Port Number :
1024
Serial Mode:
RS-485
Baudrare:
9600
Character Bits:
8
Parity Type :
none
Stop Bit :
1
Serial Port Configuration
Hardware Flow Control:
none
Topology:
Figure 4-49
Two ICS-10x configured with Pair-Connection