background image

User’s Manual of ICS-10x 

 

-24- 

 

4.2.4 Factory Default 

The 

Factory Default

 can reset the ICS-10x back to the factory default mode. Be aware that the entire configuration will be 

reset, and the IP address of the ICS-10x will be set to “

192.168.0.100”

. The screen in Figure 4-8 appears. 

 

Figure 4-8 

Factory Default progress screen 

 

 

4.2.5 System Reboot 

The 

System Reboot

 can restart the ICS-10x. The screen in Figure 4-9 appears. 

 

Figure 4-9 

System Reboot progress screen 

 

 

 

 

 

Summary of Contents for ICS-10 Series

Page 1: ...User s Manual ICS 100 ICS 101 ICS 102 ICS 102S15 ICS 105A RS 232 RS 422 RS 485 over 100Base FX 10 100Base TX Media Converter...

Page 2: ...These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio f...

Page 3: ...of ICS 10x 3 Revision PLANET RS 232 RS 422 RS 485 over 10 100Base TX 100Base FX Media Converter User s Manual FOR MODELS ICS 100 ICS 101 ICS 102 ICS 102S15 ICS 105A REVISION 1 5 APRIL 2012 Part No 20...

Page 4: ...2 2 Chassis Installation and Rack Mounting 14 3 MANAGEMENT 16 3 1 OVERVIEW 16 3 2 REQUIREMENTS 16 3 3 MANAGEMENT METHODS 17 3 3 1 Web Management 17 3 3 2 Login the Media converter 17 4 WEB CONFIGURATI...

Page 5: ...THE VCOM UTILITY 57 5 2 SEARCH THE DEVICE 60 5 3 VIRTUAL COM 61 APPENDIX A 64 A 1 PLANET SMART DISCOVERY UTILITY 64 A 2 DEVICE S RS 232 RS 422 RS 485 PIN ASSIGNMENTS 65 A 3 DEVICE S RJ 45 PIN ASSIGNME...

Page 6: ...g or damaged please contact your dealer immediately if possible retain the carton including the original packing material and use them against to repack the product in case there is a need to return i...

Page 7: ...at also makes them be able to connect to a TCP IP networking immediately Each Web Smart converter is able to manage through the Web Interface The powerful Web Smart Media Converter supports Applicatio...

Page 8: ...command settings through Fast Ethernet intranet to control the PLC the administrator and workstation There is no need to be always sets by the side of the I O machine Figure 1 2 Serial Converter for...

Page 9: ...b s Ethernet Interface Complies with IEEE 802 3 IEEE 802 3u 10 100Base TX 100Base FX standard Supports auto MDI MDI X function on RJ 45 Port Choice of fiber connector from ST SC LC multi mode single m...

Page 10: ...02 3u Fast Ethernet 10 100Base TX 100Base FX Connector RJ 45 ST SC LC Fiber Mode Multi Mode Single Mode Single Mode Multi Mode Transmission Mode Full Duplex Half Duple Full Duplex Distance 100m 2km 15...

Page 11: ...Temperature 0 50 Degree C Storage Temperature 10 70 Degree C Humidity 10 90 RH operating 5 90 RH Storage Emissions FCC Class A CE Certification Standards IEEE 802 3 Ethernet 10Base T IEEE 802 3u Fast...

Page 12: ...yourself with its display indicators and ports Front panel illustrations in this chapter display the unit LED indicators Before connecting any network device to the Serial Media Converter please read...

Page 13: ...User s Manual of ICS 10x 8 Figure 2 2 PLANET ICS 100 Front Panel ICS 101 RS 232 RS 422 RS 485 over 100Base FX ST Interface Figure 2 3 ICS 101 panel layout...

Page 14: ...User s Manual of ICS 10x 9 Figure 2 4 PLANET ICS 101 Front Panel ICS 102 ICS 102S15 RS 232 RS 422 RS 485 over 100Base FX SC Interface Figure 2 5 ICS 102 ICS 102S15 panel layout...

Page 15: ...User s Manual of ICS 10x 10 Figure 2 6 PLANET ICS 102 ICS 102S15 Front Panel ICS 105A RS 232 RS 422 RS 485 over 100Base FX LC Interface Figure 2 7 ICS 105A panel layout...

Page 16: ...en Blinks To indicate the Fast Ethernet Port is receiving or sending data Lights To indicate that the RS 232 Port is connected successfully Lights and off To indicate the RS 422 Port is receiving or s...

Page 17: ...ET button more than 10 seconds the device will back to the factory default mode the entire configuration will be erased 2 2 Install the Converter This section describes how to install your ICS 10x Web...

Page 18: ...User s Manual of ICS 10x 13 Figure 2 10 ICS 100 stand alone installation Figure 2 11 ICS 101 ICS 102 ICS 102S15 stand alone installation...

Page 19: ...the converter 2 2 2 Chassis Installation and Rack Mounting To install the Media Converter in a 10 inch or 19 inch with standard rack follow the instructions described below Step 1 Place your ICS 10x...

Page 20: ...s to securely attach the brackets to the rack as shown in Figure 2 14 Step 5 Precede with the steps 4 and steps 5 of session 2 2 1 Stand alone Installation to connect the network cabling and supply po...

Page 21: ...4 for more details 3 2 Requirements Network cables For ICS 100 Use standard network UTP cables with RJ 45 connectors For ICS 101 Use Multi mode fiber patch cord with ST connectors For ICS 102 ICS 102...

Page 22: ...e ICS 10x please note the ICS 10x is configured through an Ethernet connection make sure the manager PC must be set on same the IP subnet address For example the default IP address of the ICS 10x is 1...

Page 23: ...ser s Manual of ICS 10x 18 Figure 3 2 Login screen 1 For security reason please change and memorize the new password after this first setup 2 Only accept command in lowercase letter under web interfac...

Page 24: ...ys the converter Welcome page The screen in Figure 4 1 appears Figure 4 1 Web Main screen As listed at the left of the main screen the configurable smart functions are shown as below System Check the...

Page 25: ...me Software Version The current software version running on the device MAC Address Specifies the device MAC address IP Address The current IP Address of the device The IP Address could be manual assig...

Page 26: ...ssword is not displayed As it entered an corresponding to each character is displayed in the field The maximum length is 15 characters Confirm Password This confirms the new password The password ente...

Page 27: ...image files from the Local File browser to the device The screen in Figure 4 4 appears Figure 4 4 Firmware Upgrade screen To open Firmware Upgrade screen perform the folling 1 Click System Firmware Up...

Page 28: ...choose firmware Figure 4 7 Windows file selection menu popup 4 Select on the firmware then click Upgrade The firmware upgrade may take 60 seconds Do not power off the converter until the update progr...

Page 29: ...e aware that the entire configuration will be reset and the IP address of the ICS 10x will be set to 192 168 0 100 The screen in Figure 4 8 appears Figure 4 8 Factory Default progress screen 4 2 5 Sys...

Page 30: ...rk Once the DHCP Server get the request it will assign a dynamic IP address subnet mask and gateway to the ICS 10x The factory default setting is Disable IP Address Assign the converter IP Address The...

Page 31: ...ent becomes IP based That also makes them be able to connect to a TCP IP networking immediately The ICS 10x allow traditional Computer Client COM ports access to a serial equipment anywhere on the Eth...

Page 32: ...t of ICS 10x to wait for serial application to establish a TCP connection After the connection is established data can be transmitted in both directions The parameter defines the maintenance status fo...

Page 33: ...he se Example Use Microsoft Windows Hyper Terminal TCP IP Winsock mode e services and host computers using your modem a null modem cable a Console cable or Ethernet connection to an Ethernet Switch vi...

Page 34: ...n of IC Mode RS 232 Baudrare 9600 Character Bits 8 Parity Type none Stop Bit 1 Hardware Flow Control none Figure 4 15 Example Serial Port Configuration screen Hyper Terminal setup a new connection wit...

Page 35: ...he Icon box click the appropriate icon and then click OK Figure 4 17 Example Hyper Terminal Create new connection dem you want to use in the Connect using drop down box In this case we are connecting...

Page 36: ...dard Internet The address or name of the connection you want to create This can be in stan dotted notation for example w x y z or can be the site s user friendly name port The number of the port that...

Page 37: ...ion Figure 4 21 TCP Client mode When changed to TCP Client operation mode the screen in Figure 4 22 appears the user can change the Serial Port Configuration Figure 4 22 TCP Client Configuration scree...

Page 38: ...t or multicast It also makes the Serial device to receive data from more than one Remote Hosts The parameter defines the maintenance status for listen for the UDP connection In UDP Client mode you nee...

Page 39: ...will transfer data to Ethernet by windows socket The Virtual COM driver maps IP Address Port of ICS 10x to a local COM port on the Remote Host Computer Once the Virtual COM connection is established...

Page 40: ...eout The unit drops the connection if there is no activity on the serial line before the set time expires To disable the inactive timeout enter 0 Use the parameter to set an Example Use PLANET VCOM Ut...

Page 41: ...x 36 Setup Operation Mode and Serial Port of ICS 10x 1 From the WEB interface set the Serial operation mode of ICS 10x to Virtual COM and set the TCP Port Number to 1024 Figure 4 28 Example Virtual CO...

Page 42: ...S 10x 37 2 S erial Port Configur S 10x as below et the S ation of IC Mode RS 232 Baudrare 9600 Character Bits 8 Parity Type none Stop Bit 1 Hardware Flow Control none Figure 4 29 Example Serial Port C...

Page 43: ...port 3 This mode will run with the software PLANET VCOM Utility Open the VCOM utility click Search button to point out the ICS 10x that want to be configured Figure 4 30 Example Virtual COM Configura...

Page 44: ...screen Hyper Terminal setup a new connection with virtual COM port 5 On the File menu click New Connection 6 In the Name box give a name for the connection 7 In the Icon box click the appropriate icon...

Page 45: ...rt you want to use in the Connect using drop down box In this case choose COM9 as created in Step 4 Figure 4 33 Example HyperTerminal Configuration screen 9 Set the parameter like below click Apply to...

Page 46: ...connection is established open the VCOM utility again to check the COM9 information Figure 4 35 Example VCOM Utility COM9 information 11 Then can use the serial console cable to connect with the switc...

Page 47: ...Figure 4 37 COM port screen When changed operation mode the user should be changed the Serial Port Configuration The screen in Figure 4 38 appears Figure 4 38 Telnet Server Configuration screen The pa...

Page 48: ...tform Figure 4 39 Example Telnet Server Setup Operation Mode and Serial Port of ICS 10x 1 Set the ICS 10x mode to Telnet server mode from web interface 2 Set the Serial Port Configuration of ICS 10x a...

Page 49: ...xxx xxx xxx is the IP address of the ICS 10x Telnet Server In this case we type open 192 168 0 100 and press enter Figure 4 41 Example Windows Excuse Telnet 6 Then can use the telnet connection to con...

Page 50: ...is a free implementation of Telnet and SSH for Win32 and Unix platforms along with an xterm terminal emulator In this case we use Putty to telnet to the ICS 10x Telnet Server mode for remote console...

Page 51: ...User s Manual of ICS 10x 46 3 Then can telnet IP address like to telnet switch s IP Figure 4 45 Putty telnet screen...

Page 52: ...emote serial equipment and connect to it via serial interface Figure 4 46 Pair Connection mode In effect this converter will be acting as a TCP server The screen in Figure 4 47 appears When the change...

Page 53: ...ut Use the parameter to set an inactive timeout The unit drops the connection if there is no activity on the serial line before the set time expires To disable the inactive timeout enter 0 Important W...

Page 54: ...interface The two of the ICS 10x master and slave with below settings ICS 10x Master Connect to Control Keyboard IP Address Subnet Mask 192 168 0 100 255 255 255 0 Operation Mode Mode Pair Connection...

Page 55: ...ANET product CAM KB300 ICS 10x Master be configured as Pair Connection Local 3 From Web interface login the ICS 10x with IP address 192 168 0 100 set up the operation mode of this unit to be Pair Conn...

Page 56: ...address 192 168 0 101 set up the operation mode of this unit to be Pair Connection Remote Slave Figure 4 52 Pair Connection Remote operation mode configuration Set the Serial Port mode of ICS 10x Slav...

Page 57: ...onnection Valid baud rates It s in the range of 300bps to 921600bps Character Bits tted data package The allowed value is 5 6 7 8 Indicates the number of the bits in a transmi The default is 8 Parity...

Page 58: ...cter 2 allow the use to enter two AS a message with both there delimiters is received at the serial port the data contained in the serial buffer is paced in an Ethernet packet and sent out the Etherne...

Page 59: ...he screen in Figure 4 53 appears You may setup SMTP mail parameters for further operation If users want to send the alarm message out that contains Log Fail Warring OP Change Warning and Reboot Warnin...

Page 60: ...y e mails Log Fail Warning Subject Enter the subject title of the e mail The default subject is ICS 10x Login Fail Warming Message Body Enter the message of the e mail The default subject is ICS 10x w...

Page 61: ...User s Manual of ICS 10x 56 Figure 4 55 Login screen...

Page 62: ...a via virtual COM port The VCOM is an integrated software suite that bundles Device Server Administrator and IP Serial Library and provides something you need to monitor your ICS 10x from a remote loc...

Page 63: ...User s Manual of ICS 10x 58 3 Click Install to install the program Figure 5 2 VCOM installation screen 4 Click Finish to complete Figure 5 3 VCOM installation screen...

Page 64: ...User s Manual of ICS 10x 59 5 To run the PLANET VCOM utility on the computer click Start All Programs PLANET VCOM VCOM Figure 5 4 VCOM program path...

Page 65: ...er MAC address and IP address 1 Click the shortcut of VCOM on the desktop to run the VCOM program 2 Click Search button in Main window If any ICS 10x series device on the LAN it will show the device n...

Page 66: ...10x s operation mode to Virtual COM on the Web Choose to create port like below 1 If the device support Telnet while user click COM Mapping Figure 5 6 COM Mapping 2 While user click Add button it wil...

Page 67: ...d set up TCP Client mode COM number and RemotePort number Click OK button to create new virtual com port and establish telenet connection Figure 5 8 Add Virtual COM Port Configuration 4 Then set the H...

Page 68: ...he Virtual COM Port COM9 connection is established from the Windows Device Manager a COM Port is added to the device list Figure 5 11 Windows Device Server Virtual COM Port When the Virtual COM progra...

Page 69: ...net Smart Discovery Utility 1 Deposit the Planet Smart Discovery Utility in administrator PC 2 Run this utility and the following screen appears Figure A 1 Planet Smart Discovery Utility Screen If the...

Page 70: ...ption tools bar 3 To click the Control Packet Force Broadcast function it can allow assign new setting value to the Web Smart Switch under different IP subnet address 6 Press Connect to Device button...

Page 71: ...5 White Blue 6 Green 7 White Brown 8 Brown 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown Straight Cable SIDE 1 SIDE2 SIDE 1 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 S...

Page 72: ...5 125 m 9 125 m A 6 Power Information The power jack of ICS 10X is with 2 5mm in the central post and required 5VDC power input It will conform to the bundled AC DC adapter and Planet s Media Chassis...

Page 73: ...A2 2009 EN 61000 3 3 2008 EN 55024 2010 EN 50130 4 2011 IEC 61000 4 2 2008 IEC 61000 4 3 2006 A1 2007 A2 2010 IEC 61000 4 4 2004 A1 2010 IEC 61000 4 5 2005 IEC 61000 4 6 2008 IEC 61000 4 8 2009 IEC 6...

Reviews: