GRT-504 4-Wire G.SHDSL.bis Firewall Router User’s Manual
6.2.1.2
Line Type
There are six type of line type for you choose:
2-wire
,
M-Pair
,
M-Pair(Conexant)
,
Auto Fall Back
,
StandBy
and
Multi-link.
2-wire mode
For 4-wires model, it can use only the first one pair for the single pair DSL wire application.
M – Pair Mode
In this mode, each wire pair of SHDSL.bis router must be configured with the same line rate. If one
pair fails then the entire line must be restarted. It also has the Conexant M-pair standard used with
connection to other router with Conexant chip set solution.
Auto Fall Back Mode
Two DSL pairs are working simultaneously. When one pair of both is disconnect, the other pair will
keep working.
Stanby Mode
Only one of two pairs are working, other pair is standby. If the working pair fails, the standby pair
will start up to continues.
47