User’s Manual of SGSD-1022 / SGSD-1022P
SGSW-2840 / SGSW-2840P
72
Figure 4-2-17
System Logs screenshot
1. Click System / Log /
System Logs
.
2. Specify System Log Status, set the level of event messages to be logged to RAM and flash memory, then click Apply.
The page includes the following fields:
Object
Description
•
System Log Status
Enables/disables the logging of debug or error messages to the logging process.
(Default:
Enabled
)
•
Flash Level(0-7)
Limits log messages saved to the switch’s permanent flash memory for all levels
up to the specified level. For example, if level 3 is specified, all messages from
level 0 to level 3 will be logged to flash.
Range: 0-7,
Default:
3
•
RAM Level(0-7)
Limits log messages saved to the switch’s temporary RAM memory for all levels
up to the specified level. For example, if level 7 is specified, all messages from
level 0 to level 7 will be logged to RAM.
Range: 0-7,
Default:
7
1.
There are only Level 2, 5 and 6 error messages for the current firmware release.
2.
The Flash Level must be equal to or less than the RAM Level.