User’s Manual of IGSW-24040T
Event Description
Al
n alarming.
lows user setting a customize message for Digital Input functio
Event
As Digital Input:
Allows user to record alarm message to System log, syslog or issues out via
and SMTP are disabled, please enable them first if you
A
itor and alarm from port fail, power fail, DI1 and DI2.
SNMP Trap or SMTP.
As default SNMP Trap
want to issue alarm message via them.
s Digital Output:
Allows user to mon
Power Alarm
Allows user to choose which power module want to be monitored.
Port Alarm
Allows user to choose which port want to be monitored.
Buttons
: Click to save changes.
: Click to undo any changes made locally and revert to previously saved values.
.2.20 Fault Alarm
The Fault Relay Alarm function provides the Power Failure and Port Link Down/Broken detection. With both power input 1 and
g
4
power input 2 installed and the check boxes of power 1/power 2 ticked, the FAULT LED indicator will then be possible to light up
when any one of the power failures occurs. As for the Port Link Down/Broken detection, the FAULT LED indicator will light up
when the port failure occurs; certainly the check box beside the port must be ticked first. Please refer to the segment of ‘
Wirin
the Fault Alarm Contact
’ for the failure detection. The Configuration screen in
Figure 4-2-27
appears.
75
Summary of Contents for IGSW-24040T
Page 130: ...User s Manual of IGSW 24040T Figure 4 6 10 Port 1 Port 6 VLAN Configuration 130 ...
Page 150: ...User s Manual of IGSW 24040T 150 Figure 4 7 10 MST1 MSTI Port Configuration Page Screenshot ...
Page 188: ...User s Manual of IGSW 24040T Figure 4 9 14 Voice VLAN Configuration Page Screenshot 188 ...
Page 308: ...User s Manual of IGSW 24040T 308 ...
Page 434: ...User s Manual of IGSW 24040T Parameters vid VLAN ID 1 4095 Default Setting disable 434 ...