5/12

Example E

3 m max

3 m max

VF AF-IFGR03

VF AF-MR5

VF F05

VF AF-CA10

VF AF-TR8

4.4 Rope tightening

The maximum rope lengths listed in paragraph INSTALLATION EXAMPLES are 

reduced, if the ambient temperature is subject to considerable variations.
The max. recommended lengths are indicated in the following diagram in accordance 

with the temperature fluctuations (temperature differences) to which the switch may 

be exposed at the point of use.
The values indicated in the graph are guaranteed only for use of the original rope and 

accessories.

0

5

10

15

20

25

30

0

10

20

30

40

50

60

70

80

90

100

Temperature difference 

Δ

T (°C)

Max. rope length (m)

Example A

Example B

Example C, E

Example D

4.5 Electrical connections

 Attention: The safety circuit must be connected to NC contacts 11 - 21; contacts 

12 - 22 must be connected in series, as shown in the following diagram

.

A

1

2

3

11

12

11

12

21

22

11

12

21

22

A

B

C

Legend
1 Start button
2 Stop button
3 Fuse

A Tensioned rope
B Cut or disconnected rope
C Pulled rope

 5 OPERATION

Once you have affixed the device to the machine, connected and tensioned 
the actuation rope, and made the electrical connections as described in the 
"INSTALLATION INSTRUCTIONS" paragraph, pulling on the rope must cause the 
electrical contacts inside the device to open.

 6 INSTRUCTIONS FOR PROPER USE

6.1 Installation

- Tighten the fixing screws of electrical conductors to a torque from 0.6 to 0.8 Nm.

- Do not stress the device with bending and torsion.

- Do not modify the device for any reason.

- Do not exceed the tightening torques specified in the present manual.

- The device carries out an operator protection function. Any inadequate installation 

or tampering can cause serious injuries and even death, property damage, and 

economic losses.

- These devices must not be bypassed, removed, turned or disabled in any other way.

- If the machine where the device is installed is used for a purpose other than that 

specified, the device may not provide the operator with efficient protection.

- The safety category of the system (according to EN ISO 13849-1), including the safe-

ty device, also depends on the external components connected to it and their type.

- Before installation, make sure the device is not damaged in any part.

- Avoid excessive bending of connection cables in order to prevent any short circuits 

or power failures.

- Do not paint or varnish the device.

- Do not drill the device.

- Do not use the device as a support or rest for other structures, such as raceways, 

sliding guides or similar.

- Before commissioning, make sure that the entire machine (or system) complies with 

all applicable standards and EMC directive requirements.

- The fitting surface of the device must always be smooth and clean.
- The documents necessary for a correct installation and maintenance are always 

available in the following languages: English, French, German and Italian.

- Should the installer be unable to fully understand the documents, the product must 

not be installed and the necessary assistance may be requested (see paragraph 
SUPPORT).

- Always attach the following instructions to the manual of the machine in which the 

device is installed.

- These operating instructions must be kept available for consultation at any time and 

for the whole period of use of the device.

6.2 Do not use in the following environments

- In environments where continual changes in temperature cause the formation of 

condensation inside the device.

- In environments where the application causes collisions, impacts or strong vibrations 

to the device.

- In environments containing explosive or inflammable gases or dusts. 
- In environments where ice can form on the device.
- In environments containing strongly aggressive chemicals, where the products used 

coming into contact with the device may impair its physical or functional integrity.

6.3 Maintenance and functional tests

 Attention: Never disassemble or attempt to repair the device, rope, or acces-

sories. Should an anomaly or fault occur, replace the device, rope, or accessories.

 Attention: Should the device, rope, or accessories become damaged or worn, 

always replace them immediately. Correct operation cannot be guaranteed when the 
device, rope, or accessories are deformed or damaged.
- The installer is responsible for establishing the sequence of functional tests to which 

the device is to be subjected before the machine is started up and during mainte-
nance intervals. 

- The sequence of the functional tests can vary depending on the machine complexity 

and circuit diagram, therefore the functional test sequence detailed below is to be 
considered as minimal and not exhaustive.

- Perform the following sequence of checks before the machine is commissioned and 

at least once a year (or after a prolonged shutdown):

1) Check correct tensioning of the rope as described in the INSTALLATION INSTRUC-

TIONS paragraph. 

2) Pull the rope when the machine is moving. The machine must stop.
3) Keeping the rope pulled, try to start the machine. The machine must not start.
4) Check that the rope is affixed to the stay bolts and end terminals correctly and, if 

necessary, re-affix the rope as described in paragraph INSTALLATION INSTRUC-
TIONS.

5) All external parts must be undamaged.
6) Carefully check the condition of the external rope covering. If you discover cracks 

or colour variations that could impede the function of the rope itself, replace the 
entire rope.

7) Ropes, pulleys, terminals, jumpers, and stay bolts must be in good condition, and 

firmly attached.

8) If the device or an accessory is damaged, replace it completely.
- The device and related accessories have been created for applications in dangerous 

environments, and they therefore have a limited service life. After 20 years from the 
production date, the device and related accessories must be replaced entirely; even 
if they still work. The date of manufacture is positioned adjacent to the product code 
(see paragraph MARKINGS).

6.4 Wiring

- Keep the charge within the values specified in the electrical operation categories.
- Only connect and disconnect the device when the power is off.
- During and after the installation do not pull the electrical cables connected to the 

device. If traction is applied to the cables (not supported by an appropriate cable 
gland) internal parts of the device may be damaged.

- Always connect the protection fuse (or equivalent device) in series to the safety 

electrical contacts.

- At the end of the wiring, check that no contaminating element has been introduced 

inside the device.

- Before closing the device cover verify the correct positioning of the gaskets.
- Verify that the electrical cables, wire-end sleeves, cable numbering systems and any 

other parts do not obstruct the cover from closing correctly or if pressed between 
them do not damage or compress internal parts.

- Adhere to the following minimum and maximum cross-sections of electrical 

conductors designed for screw terminals: 
min 1 x 0.5 mm

(1 x AWG 20)

max 2 x 2.5 mm

(2 x AWG 14)

- The stripping length of the cable or wire end sleeve must be 8 mm.

8 mm

6.5 Additional prescriptions for safety applications with operator protection 
functions

Provided that all previous requirements for the devices are fulfilled, for installations 
with operator protection function additional requirements must be observed.
- The utilization implies knowledge of and compliance with following standards: 
EN 60947-5-3, EN ISO 13849-1, EN 62061, EN 60204-1, EN ISO 14119, 
EN ISO 12100.

Summary of Contents for FD 874

Page 1: ...umit degli operatori e la conformit a norme o direttive specifiche per la sicurezza delle macchine Prima di installare un dispositivo di protezione necessario eseguire un analisi del rischio specifica...

Page 2: ...e la formazione di manicotti di ghiaccio sul dispositivo In ambienti fortemente chimico aggressivi dove i prodotti utilizzati che vengono a contatto con il dispositivo possono comprometterne l integri...

Page 3: ...3 Ue V 24 125 250 Ie A 3 0 55 0 3 8 3 2 Versioni con connettore M12 a 4 o 5 poli Corrente termica Ith 4 A Tensione nominale di isolamento Ui 250 Vac 300 Vdc Protezione dai cortocircuiti fusibile 4 A 5...

Page 4: ...mpliance with machine safety standards or directives Before installing a protec tive device perform a specific risk analysis in accordance with the key health and safety requirements in the Machinery...

Page 5: ...ere ice can form on the device In environments containing strongly aggressive chemicals where the products used coming into contact with the device may impair its physical or functional integrity 6 3...

Page 6: ...rrent Ith 4 A Rated insulation voltage Ui 250 Vac 300 Vdc Protection against short circuits type gG fuse 4 A 500 V Pollution degree 3 Utilization categories Alternating current AC15 50 60 Hz Ue V 24 1...

Page 7: ...RUCTIONS DE MONTAGE Attention L installation d un dispositif de protection ne suffit pas garantir la s curit des op rateurs et le respect de normes ou de directives sp cifiques en ma ti re de s curit...

Page 8: ...nnement dans lequel l application comporte des vibrations et des chocs im portants pour le dispositif Environnement expos des poussi res ou gaz explosifs ou inflammables Dans des espaces o des manchon...

Page 9: ...el 1000 A selon EN 60947 5 1 Protection contre les courts circuits fusible 10 A 500 V type aM Degr de pollution 3 Cat gories d utilisation Courant alternatif AC15 50 60 Hz Ue V 250 400 500 Ie A 6 4 1...

Page 10: ...und Konformit t zu Nor men oder Richtlinien zur Maschinensicherheit herzustellen Vor Installation einer Schutzeinrichtung muss eine spezifische Risikobeurteilung gem den grundlegen den Anforderungen d...

Page 11: ...atz in folgenden Bereichen Umgebungen in denen st ndige Temperaturschwankungen zu Kondensation im Ger t f hren k nnen Umgebungen in denen das Ger t anwendungsbedingt Kollisionen St en oder starken Vib...

Page 12: ...ationsspannung Ui 500 Vac 600 Vdc Bemessungssto spannungsfestigkeit Uimp 6 kV Bedingter Kurzschlussstrom 1000 A gem EN 60947 5 1 Kurzschlussschutz Sicherung 10 A 500 V Typ aM Verschmutzungsgrad 3 Gebr...

Reviews: