background image

Pizzato Elettrica Srl
via Torino, 1
36063 MAROSTICA (VI)
ITALY

e-mail: [email protected]
web site:  www.pizzato.com

Phone:   +39.0424.470.930

ZE FOG42A19-EU

4/12

 1 INFORMATION ON THIS DOCUMENT

1.1 Function

The present operating instructions provide information on installation, connection and 
safe use for the following articles: 

CS ME-30••••, CS ME-31••••

.

1.2 Target audience

The operations described in these operating instructions must be carried out by quali-
fied personnel only, who are fully capable of understanding them, and with the techni-
cal qualifications required for operating the machines and plants in which the safety 
devices are to be installed.

1.3 Application field

These instructions apply exclusively to the products listed in paragraph Function, and 
their accessories.

1.4 Original instructions

The Italian language version is the original set of instructions for the device. Versions 
provided in other languages are translations of the original instructions.

 2 SYMBOLS USED

 This symbol indicates any relevant additional information

 Attention: Any failure to observe this warning note can cause damage or mal-

function, including possible loss of the safety function.

 3 DESCRIPTION

3.1 Device description

The safety device described in this manual is defined according to the Machinery 
Directive 2006/42/EC as logic component for safety functions.
The contact expansion modules to which these usage instructions apply are devices 
specifically designed and manufactured for use on industrial machines. Upon opening 

of at least one channel, the safety function ensures that the safety relay must open its 
output contacts within the defined release time.

3.2 Device functions

 This device is suitable for the following applications: as contact expansion mod-

ule in safety circuits up to category 4 acc. to EN ISO 13849-1, up to SIL 3 acc. to 
EN 62061 and up to PL e acc. to EN ISO 13849-1 (the respective achievable category, 
SIL and PL are dependent on the upstream safety module).
- Possibility for 1- or 2-channel control.
- Connection of input channels of opposite potentials.
- Output contacts: 4 NO safety contacts, 2 NC auxiliary contacts, 1 NC feedback 
contact.
- Versions with permanent or adjustable delay times.
- LED indicators for switching state of the channels 1 and 2.
- Screw terminals or plug-in terminals with screw connections or spring terminals (de-
pending on the model).
- Snap-mounting on DIN rails.

3.3 Intended use of the device

- The device described in these operating instructions is designed to be applied on 
industrial machines.
- The direct sale of this device to the public is prohibited. Installation and use must be 
carried out by qualified personnel only.
- The use of the device for purposes other than those specified in these operating 
instructions is prohibited.
- Any use other than as expressly specified in these operating instructions shall be 
considered unintended by the manufacturer. 
- Also considered unintended use:
a) using the device after having made structural, technical, or electrical modifications 
to it;
b) using the product in a field of application other than as described in paragraph 
TEChNICAL DATA.

 4 OPERATION

4.1 Operating diagram

CS ME30

••••

CS ME31

••••

A1/A2

Y1/Y2
17/18, 27/28, 
37/38, 47/48

t

A

t

R

55/56, 65/66

Legend:

t

A

:

 Response time

t

R

:

 Release time in absence of power supply

NOTE: The release time in the absence of power supply t

R

 is permanently set to x 

seconds for articles CS ME-30••••-TFx, while with articles CS ME-31••••-TSx it can be 

set in increments of 1 second in the range from 1 to 12 seconds.

4.2 Selection of the release time t

R

 (CS ME-31••••-TS12 articles only)

With article CS ME-31••••-TS12, the release time t

R

 can be selected in increments 

of 1 second in the range from 1 to 12 seconds. The setting is performed with the dip 
switch on the front side of the expansion module.

DIP SWITCH

t

R

ON

1 s

OFF

ON

2 s

OFF

ON

3 s

OFF

ON

4 s

OFF

ON

5 s

OFF

ON

6 s

OFF

DIP SWITCH

t

R

ON

7 s

OFF

ON

8 s

OFF

ON

9 s

OFF

ON

10 s

OFF

ON

11 s

OFF

ON

12 s

OFF

4.2 Wiring diagrams

1-channel control

13

14

A2

Y1

Y2

A1

F

L / +

N / -

2-channel control

13

14

A2

Y1

Y2

A1

23

24

F

L / +

N / -

 5 INTERNAL WIRING DIAGRAM

K1

K2

A1

17

27

65

A2

18

28

66

37

47

38

48

55

56

C2

C1

LED
CH1

LED
CH2

Y1

Y2

L / +

N / -

 : 

Insulated against U

imp

CS ME-30 / CS ME-31  

expansion module

Manual start

Automatic start

Start input,  
reset and/or feedback

Base module

CS ME-30 / CS ME-31  

expansion module

Manual start

Automatic start

Start input, reset 
and/or feedback

Base module

Summary of Contents for CS ME-30 Series

Page 1: ...i NC di segnalazione 1 contatto NC di retroazione Versioni con tempi di ritardo fissi o selezionabili Indicatori LED dello stato di commutazione dei canali 1 e 2 Morsetti con connessione a vite oppure...

Page 2: ...ti nei morsetti e nei connet tori 4 Verificare che il comportamento del modulo in funzione rispetti i diagrammi di fun zionamento riportati nel paragrafo funzionamento Il dispositivo nasce per applica...

Page 3: ...uso L installatore deve assicurarsi di aver ricevuto vedi paragrafo SUPPORTO informa zioni scritte in merito all utilizzo della versione speciale richiesta 11 SMALTIMENTO Il prodotto deve essere smal...

Page 4: ...C auxiliary contacts 1 NC feedback contact Versions with permanent or adjustable delay times LED indicators for switching state of the channels 1 and 2 Screw terminals or plug in terminals with screw...

Page 5: ...a limited service life Although still functioning after 20 years from the date of manufacture the device must be replaced completely The date of manufacture is placed next to the product code see par...

Page 6: ...ople s physical safety therefore in case of any doubt concerning installation or operation methods always contact our technical support service Pizzato Elettrica Srl Via Torino 1 36063 Marostica VI IT...

Page 7: ...ntacts NC de signalisation 1 contact NC de r troaction Versions avec temps de retard fixes ou s lectionnables Indicateurs LED de l tat de commutation des canaux 1 et 2 Bornes avec connexion vis ou bor...

Page 8: ...es c bles lectriques sont solidement positionn s dans les bornes et dans les connecteurs 4 V rifier que le module se comporte en fonctionnement comme repr sent dans les diagrammes de fonctionnement pr...

Page 9: ...pr sente mode d emploi L installateur doit s assurer qu il a bien re u voir paragraphe SUPPORT toutes les informations crites concernant l utilisation de la version sp ciale demand e 11 LIMINATION Le...

Page 10: ...kte 2 NC Meldekontakte 1 NC R ckf hrkontakt Ausf hrungen mit festen oder einstellbaren Verz gerungszeiten LED Anzeigen f r den Schaltzustand der Kan le 1 2 Schraubklemmen oder steckbare Klemmenbl cke...

Page 11: ...n dass die elektrischen Kabel fest in den Klemmen und Anschl ssen sitzen 4 berpr fen dass das Modul sich im Betrieb entsprechend der im Abschnitt Be trieb aufgef hrten Ablaufdiagramme verh lt Das Ger...

Page 12: ...den Beschreibungen in vorlie gender Betriebsanleitung abweichen Der Installateur muss sich vergewissern dass er schriftliche Informationen zum Ge brauch der spezifischen Ger teversion vgl Abschnitt KU...

Reviews: