15
/124
15
/48
EN
This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
translated from Italian
FULL PACK MC BOX etl
10
TECHNICAL SPECIFICATIONS
INTENDED USE
Implementation of a system for the dispensing and control of fluids for
private use not subject to special regulations such as ATEX for potentially
explosive environments.
WARNING
DO NOT INSTALL MC BOX B.SMART IN ENVIRONMENTS CLASSIFIED
AS POTENTIALLY EXPLOSIVE IN ACCORDANCE WITH ATEX
REGULATIONS.
MAXIMUM
VARIATIONS
IN
ELECTRICAL
PARAMETERS
The motors in the dispensers accept maximum variations:
of supply voltage by +/- 5%
and maximum frequency variations of +/- 2%
SEE TECHNICAL SPECIFICATIONS TABLE BELOW
WARNING
BEFORE INSTALLATION, ALWAYS CHECK THAT your MODEL IS
CORRECT AND SUITABLE FOR THE SUPPLY EFFECTIVELY AVAILABLE
(VOLTAGE / FREQUENCY).
Signal
Standard
conditions
Limits
Notes
Power supply
input
100-240 V ac
Maximum power
absorbed in stand-by
of 5W
The electronic board is equipped with
a switching technology power supply
that allows a wide range of voltages
and frequencies and therefore makes
the equipment robust for the high
fluctuations of voltage or frequency
present on the power distribution
mains in many areas of the world
Motor piloting
output
100-240 V ac
Imax 15 A
Electronic key
interface
YELLOW key
(iButton): Enabling
input by PIUSI
electronic key
Through a software
procedure, the yellow
keys of the drivers are
registered on the PC
and then these drivers
are enabled on one
or more dispensing
stations
You can configure whether or not
such a key is present
Nozzle contact
input
(only for
versions where
available)
Clean contact or
Open Collector
(NPN) electronic
signal
About 250 uA at 5 V
dc will be supplied on
the clean contact (or
on the open collector)
It is possible to configure whether or
not this contact is present, and it is
also possible to configure the type
of signal (normally open or normally
closed)
Pulser IN input
Free contact or
Open Collector
(NPN) electronic
signal
About 250 uA at 5 V
dc will be supplied on
the clean contact (or
on the open collector)
The input signal can
have a maximum
frequency of 300
Hz with a Duty Cycle
between 20% and
80%
The input signal can have a maximum
frequency of 300 Hz with a Duty
Cycle between 20% and 80%